Research on the Propagation Characteristics of Partial Discharge Signals in 10kV Three-Phase Cable

Currently, damped AC (DAC) voltage technique is extensively used in the field of insulation defect detection for 10 kV distribution cables. However, with the ongoing efforts to improve quality and efficiency in power enterprises, researchers have proposed conducting simultaneous three-phase partial discharge tests during DAC voltage experiments. Yet, the propagation characteristics of partial discharge signals across different phases during simultaneous detection remain under-researched. This paper employs the ATP-EMTP electromagnetic transient software to establish a simulation model, a typical three-phase distribution cable model was established using the LCC module, and a partial discharge source based on the three-capacitor model was positioned in the middle section of the cable. At the connection point between the DAC high voltage output and the three-phase cable, the three-phase partial discharge detection unit facilitates the detection of partial discharge signals across the three phases and isolates the high-frequency signal transmission channels between phases. By analyzing the simulation data from the partial discharge detection, the feasibility and effectiveness of conducting simultaneous three-phase partial discharge testing during DAC testing have been validated.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/icepg63230.2024.10775962
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Propagation Characteristics of Partial Discharge Signals in 10kV Three-Phase Cable

Lu Pu, Yuan Yan, Zhé Hóu, Zeli Ju et al.
Power Systems and Technologies
article

Research on the Propagation Characteristics of Partial Discharge Signals in 10kV Three-Phase Cable

Lu Pu, Yuan Yan, Zhé Hóu, Zeli Ju, Kai Yang, Bo Yang
article en

Abstract

Currently, damped AC (DAC) voltage technique is extensively used in the field of insulation defect detection for 10 kV distribution cables. However, with the ongoing efforts to improve quality and efficiency in power enterprises, researchers have proposed conducting simultaneous three-phase partial discharge tests during DAC voltage experiments. Yet, the propagation characteristics of partial discharge signals across different phases during simultaneous detection remain under-researched. This paper employs the ATP-EMTP electromagnetic transient software to establish a simulation model, a typical three-phase distribution cable model was established using the LCC module, and a partial discharge source based on the three-capacitor model was positioned in the middle section of the cable. At the connection point between the DAC high voltage output and the three-phase cable, the three-phase partial discharge detection unit facilitates the detection of partial discharge signals across the three phases and isolates the high-frequency signal transmission channels between phases. By analyzing the simulation data from the partial discharge detection, the feasibility and effectiveness of conducting simultaneous three-phase partial discharge testing during DAC testing have been validated.

State Grid Corporation of China (China) (CN), Xi'an Jiaotong University (CN)
Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 80%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.