0.4 Research on common mode voltage cancellation strategy for four-module motor driven by parallel balanced inverter

In response to the issues of common mode voltage and the resultant common mode currents and leakage currents in PWM motor drive systems, this paper proposes a topology using a parallel balanced inverter to drive a four-module motor. Traditional three-phase inverters, with an odd number of bridge arms, inherently struggle to eliminate common mode voltage. By employing a balanced inverter, the proposed method extends the degrees of freedom, achieving internal group common mode voltage cancellation. Furthermore, replacing the conventional three-phase motor with a four-module motor and altering the stator winding connections, combined with a carrier phaseshifting modulation strategy, allows the system to cancel common mode voltages using a parallel balanced inverter. To verify the efficacy of the proposed solution, a simulation of a parallel balanced inverter driving a four-module motor system was constructed and compared with a traditional three-phase inverter system. The simulation results demonstrate that the new topology effectively suppresses system-conducted interference, thereby improving the system’s electromagnetic interference performance.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/icepg63230.2024.10775864
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0.4 Research on common mode voltage cancellation strategy for four-module motor driven by parallel balanced inverter

F. C. Lee, Yanwei Du, Yongqing Meng, Jinpeng Kan et al.
Multilevel Inverters and Converters
article

0.4 Research on common mode voltage cancellation strategy for four-module motor driven by parallel balanced inverter

F. C. Lee, Yanwei Du, Yongqing Meng, Jinpeng Kan, Wenjie Chen, Yixin Shi
article en

Abstract

In response to the issues of common mode voltage and the resultant common mode currents and leakage currents in PWM motor drive systems, this paper proposes a topology using a parallel balanced inverter to drive a four-module motor. Traditional three-phase inverters, with an odd number of bridge arms, inherently struggle to eliminate common mode voltage. By employing a balanced inverter, the proposed method extends the degrees of freedom, achieving internal group common mode voltage cancellation. Furthermore, replacing the conventional three-phase motor with a four-module motor and altering the stator winding connections, combined with a carrier phaseshifting modulation strategy, allows the system to cancel common mode voltages using a parallel balanced inverter. To verify the efficacy of the proposed solution, a simulation of a parallel balanced inverter driving a four-module motor system was constructed and compared with a traditional three-phase inverter system. The simulation results demonstrate that the new topology effectively suppresses system-conducted interference, thereby improving the system’s electromagnetic interference performance.

Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 80%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

0.4 Research on common mode voltage cancellation strategy for four-module motor driven by parallel balanced inverter — F. C. Lee, Yanwei Du, et al. · (2024) | TGRS Research Map | TGRS