Advanced Technique for EEG and HRV Measurement Using Around-Ear Capacitive Electrodes

Long-term electroencephalogram (EEG) monitoring requires devices that are unobtrusive, comfortable, and user-friendly. Capacitive electrodes, unlike gel or dry electrodes, do not require direct galvanic skin contact, making them ideal for extended use. This paper investigates the efficacy of capacitive electrodes for recording four biopotential channels from around-ear areas. A printed circuit board was developed and assessed through an alpha-block experiment. The posterior-ear capacitive EEG achieved a statistically significant power gain (APSD) of 2.77 dB in the alpha band and 5.84 dB at 10 Hz. Additionally, a mean absolute error (MAE) of 8.9 milliseconds was observed between heart rate variability (HRV) measurements from a capacitive superior-ear electrode and shoulder ECG. These results indicate that around-ear capacitive electrodes are suitable for multimodal biopotential applications, offering a promising solution for long-term EEG monitoring.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780484
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Technique for EEG and HRV Measurement Using Around-Ear Capacitive Electrodes

Anubha Kalra, Andrew Lowe, Imran Khan Niazi, Usman Qamar Shaikh
EEG and Brain-Computer Interfaces
article

Advanced Technique for EEG and HRV Measurement Using Around-Ear Capacitive Electrodes

Anubha Kalra, Andrew Lowe, Imran Khan Niazi, Usman Qamar Shaikh
article en

Abstract

Long-term electroencephalogram (EEG) monitoring requires devices that are unobtrusive, comfortable, and user-friendly. Capacitive electrodes, unlike gel or dry electrodes, do not require direct galvanic skin contact, making them ideal for extended use. This paper investigates the efficacy of capacitive electrodes for recording four biopotential channels from around-ear areas. A printed circuit board was developed and assessed through an alpha-block experiment. The posterior-ear capacitive EEG achieved a statistically significant power gain (APSD) of 2.77 dB in the alpha band and 5.84 dB at 10 Hz. Additionally, a mean absolute error (MAE) of 8.9 milliseconds was observed between heart rate variability (HRV) measurements from a capacitive superior-ear electrode and shoulder ECG. These results indicate that around-ear capacitive electrodes are suitable for multimodal biopotential applications, offering a promising solution for long-term EEG monitoring.

New Zealand College of Chiropractic (NZ), Auckland University of Technology (NZ)
Affordable and clean energy
Openalex Percentile: Top 77%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.