Research on an Anti direct current Transformer Detection Device

With the diversification of electrical equipment, more and more DC (direct current) components are added to AC (alternating current) metering circuits, resulting in traditional AC transformers being unable to correctly capture DC signals and causing inaccurate electricity metering. To solve this problem, an anti DC transformer was designed, and a detection device was developed in this paper to meet the calibration requirements of anti DC transformers. The device consists of an anti DC transformer calibrator, a digital synthesized wave AC/DC high current source, an AC/DC current ratio standard, a calibration platform, a programmable load box, and corresponding calibration software. Compared to traditional transformer calibration devices, this article has added calibration functions for power frequency ratio errors with DC components, ratio errors under sinusoidal half wave currents, phase errors, as well as ratio errors and phase errors of harmonic currents in the design. Practical application has shown that the device is stable and reliable, with fast verification speed, wide testing range, and accurate testing data.

Authors

Institutions

Publication Details

Published
2024-09-27
DOI
https://doi.org/10.1109/icepg63230.2024.10775971
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on an Anti direct current Transformer Detection Device

Haoyan Zhuang, Guang Ye, Danhong Chen, Hongwu Wen et al.
Magnetic Field Sensors Techniques
article

Research on an Anti direct current Transformer Detection Device

Haoyan Zhuang, Guang Ye, Danhong Chen, Hongwu Wen, Yichen Xie
article en

Abstract

With the diversification of electrical equipment, more and more DC (direct current) components are added to AC (alternating current) metering circuits, resulting in traditional AC transformers being unable to correctly capture DC signals and causing inaccurate electricity metering. To solve this problem, an anti DC transformer was designed, and a detection device was developed in this paper to meet the calibration requirements of anti DC transformers. The device consists of an anti DC transformer calibrator, a digital synthesized wave AC/DC high current source, an AC/DC current ratio standard, a calibration platform, a programmable load box, and corresponding calibration software. Compared to traditional transformer calibration devices, this article has added calibration functions for power frequency ratio errors with DC components, ratio errors under sinusoidal half wave currents, phase errors, as well as ratio errors and phase errors of harmonic currents in the design. Practical application has shown that the device is stable and reliable, with fast verification speed, wide testing range, and accurate testing data.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 80%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.