Measurement of Corrective Force Changes Under Scoliosis Brace in Different Spine Postures

Brace has been commonly customized for patients with adolescent idiopathic scoliosis (AIS). The corrective force generated by the brace is often considered to be applied statically at the fixed torso location defined by the orthotist when the patient is standing upright. However, despite being stabilized by the brace, daily spine movements still occur, and the changes in the magnitude and distribution of corrective forces across different spine postures remain implicit. This study proposes a method to measure pressure distributions under a thoracolumbosacral orthosis (TLSO) worn by an AIS patient using a self-developed pressure monitoring system. A total of 100 sensors were placed all over the interior surface of the brace. Contact pressures were measured in ten static spine postures and during walking and jogging. The results showed that the magnitude and distribution of corrective forces varied across different postures and movements, with the location of the maximum corrective force shifting from the intended torso location, potentially decreasing the effectiveness of the brace. The findings provide valuable insights for orthotists to assess brace effectiveness through quantifying changes in corrective forces.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780562
Citations
1
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Corrective Force Changes Under Scoliosis Brace in Different Spine Postures

Fan Feng, Quan Li, Xinyang Tan, Jiawen Wang
1 citations
Medical Imaging and Analysis
0.18
article

Measurement of Corrective Force Changes Under Scoliosis Brace in Different Spine Postures

Fan Feng, Quan Li, Xinyang Tan, Jiawen Wang
article en
1 citations

Abstract

Brace has been commonly customized for patients with adolescent idiopathic scoliosis (AIS). The corrective force generated by the brace is often considered to be applied statically at the fixed torso location defined by the orthotist when the patient is standing upright. However, despite being stabilized by the brace, daily spine movements still occur, and the changes in the magnitude and distribution of corrective forces across different spine postures remain implicit. This study proposes a method to measure pressure distributions under a thoracolumbosacral orthosis (TLSO) worn by an AIS patient using a self-developed pressure monitoring system. A total of 100 sensors were placed all over the interior surface of the brace. Contact pressures were measured in ten static spine postures and during walking and jogging. The results showed that the magnitude and distribution of corrective forces varied across different postures and movements, with the location of the maximum corrective force shifting from the intended torso location, potentially decreasing the effectiveness of the brace. The findings provide valuable insights for orthotists to assess brace effectiveness through quantifying changes in corrective forces.

Shanghai Jiao Tong University (CN), Renji Hospital (CN)
National Natural Science Foundation of China, Shanghai Municipal Education Commission
Openalex Percentile: Top 50%
Medical Imaging and Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.