Reagent-Less Low-Concentration Cortisol Detection Enabled by Laser-Induced Graphene Electrodes

Electrochemical sensors are crucial for medical diagnostics and on-body biomarker monitoring due to their high sensitivity, low cost, and miniaturization capability. This study presents a novel reagent-less molecularly imprinted polymer (MIP)-based cortisol sensor using a laser-induced graphene (LIG) electrode. The LIG electrodes were fabricated by converting polyimide substrates with a CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> laser and modified with Prussian Blue (PB) stabilized by Nickel Hexacyanoferrate (NiHCF). The high surface area and porosity of LIG enhanced the stability and adhesion of PB nanoparticles, leading to exceptional redox signal stability in 0.1 M KCl. Compared to a conventional screen-printed carbon electrode (SPCE), the LIG-based sensor exhibited higher sensitivity, a lower limit of detection (173.3 pM), and a wider dynamic range (1 nM - 100 μM) for cortisol detection, as demonstrated by square wave voltammetry (SWV). The LIG sensor effectively detected cortisol at 1 nM below the physiological range, suitable for real-time stress monitoring and medical diagnostics. This study highlights LIG as a superior transduction material, enhancing the MIP-based sensors' capability to detect low-concentration analytes. The findings offer a cost-effective and scalable approach for advanced biosensing applications.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780732
Primary Topic
Pharmacological Effects and Assays
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reagent-Less Low-Concentration Cortisol Detection Enabled by Laser-Induced Graphene Electrodes

Rourke Sylvain, Vivian Torres Vera, Smitha Rao, Grace Dykstra et al.
Pharmacological Effects and Assays
article

Reagent-Less Low-Concentration Cortisol Detection Enabled by Laser-Induced Graphene Electrodes

Rourke Sylvain, Vivian Torres Vera, Smitha Rao, Grace Dykstra, Yixin Liu, Tyler Waslawski
article en

Abstract

Electrochemical sensors are crucial for medical diagnostics and on-body biomarker monitoring due to their high sensitivity, low cost, and miniaturization capability. This study presents a novel reagent-less molecularly imprinted polymer (MIP)-based cortisol sensor using a laser-induced graphene (LIG) electrode. The LIG electrodes were fabricated by converting polyimide substrates with a CO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> laser and modified with Prussian Blue (PB) stabilized by Nickel Hexacyanoferrate (NiHCF). The high surface area and porosity of LIG enhanced the stability and adhesion of PB nanoparticles, leading to exceptional redox signal stability in 0.1 M KCl. Compared to a conventional screen-printed carbon electrode (SPCE), the LIG-based sensor exhibited higher sensitivity, a lower limit of detection (173.3 pM), and a wider dynamic range (1 nM - 100 μM) for cortisol detection, as demonstrated by square wave voltammetry (SWV). The LIG sensor effectively detected cortisol at 1 nM below the physiological range, suitable for real-time stress monitoring and medical diagnostics. This study highlights LIG as a superior transduction material, enhancing the MIP-based sensors' capability to detect low-concentration analytes. The findings offer a cost-effective and scalable approach for advanced biosensing applications.

Michigan Technological University (US)
National Science Foundation
Clean water and sanitation
Openalex Percentile: Top 73%
Pharmacological Effects and Assays
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.