Validation of WeBe Band During Physical Activities

Data reliability and algorithm robustness are both important for wearable devices. To validate the accuracy of a recently published research vehicle, WeBe band, we conducted a concurrent heart rate (HR) and galvanic skin response (GSR) validity study. WeBe band, Empatica E4 and MindWare, which is currently considered the gold standard for collecting these measures, are compared concurrently. Fifty healthy adult partic-ipants volunteered (female n=29, 49 in 18–25 age range, 1 in 26–30 age range; [mean (SD)]: height = 167.6 (8.9) cm, mass = 150.1 (33.1) lbs). Participants wore the WeBe band and the Empatica band on opposite wrists (alternating device placement between participants) and the MindWare electrodes were placed on the on chest, back, and palms. Each participant completed a study session (a total 51 minutes) that included sitting, standing, normal paced walking and faster paced walking. Data was processed and validity was measured though: mean absolute percent error (MAPE), Bland-Altman limits of aggreement (LOA) and concordance coefficient (r<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</inf>). Results showed that WeBe band is valid under all conditions.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780730
Citations
2
Primary Topic
Winter Sports Injuries and Performance
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of WeBe Band During Physical Activities

Houman Homayoun, Sally Hang, Ruoyu Zhang, Camelia E. Hostinar et al.
2 citations
Winter Sports Injuries and Performance
0.84
article

Validation of WeBe Band During Physical Activities

Houman Homayoun, Sally Hang, Ruoyu Zhang, Camelia E. Hostinar, Setareh Rafatirad, Chongzhou Fang, Ruijie Fang
article en
2 citations

Abstract

Data reliability and algorithm robustness are both important for wearable devices. To validate the accuracy of a recently published research vehicle, WeBe band, we conducted a concurrent heart rate (HR) and galvanic skin response (GSR) validity study. WeBe band, Empatica E4 and MindWare, which is currently considered the gold standard for collecting these measures, are compared concurrently. Fifty healthy adult partic-ipants volunteered (female n=29, 49 in 18–25 age range, 1 in 26–30 age range; [mean (SD)]: height = 167.6 (8.9) cm, mass = 150.1 (33.1) lbs). Participants wore the WeBe band and the Empatica band on opposite wrists (alternating device placement between participants) and the MindWare electrodes were placed on the on chest, back, and palms. Each participant completed a study session (a total 51 minutes) that included sitting, standing, normal paced walking and faster paced walking. Data was processed and validity was measured though: mean absolute percent error (MAPE), Bland-Altman limits of aggreement (LOA) and concordance coefficient (r<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</inf>). Results showed that WeBe band is valid under all conditions.

University of California, Davis (US)
Openalex Percentile: Top 22%
Winter Sports Injuries and Performance
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.