A Wearable Smart Ring for Measuring Bioimpedance in the Palmar Digital Arteries

Bioimpedance (BioZ) is a non-invasive and low-cost technology capable of monitoring conductivity rapidly. BioZ holds promise for integration into wearable devices for outpatient monitoring. Here, we propose the integration of BioZ into a smart ring form factor using electrodes coated with poly(3,4-ethylenedioxythiophene) (PEDOT) conductive polymer. PEDOT reduces contact electrode impedance by increasing the effective contact area at the skin-electrode interface and having high ionic conductivity. In this feasibility study, we developed a ring sensor, deposited PEDOT on the electrodes, and compared its capability to record pulsatile BioZ data at the finger against untreated electrodes. We performed electrochemical impedance spectroscopy (EIS) and BioZ measurements. EIS results showed that electrode contact impedance decreased by a factor of 1.2 compared to the untreated electrodes at the relevant frequency. Our results show the capability of our smart ring sensor to detect pulsatile BioZ at the digital arteries.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780710
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wearable Smart Ring for Measuring Bioimpedance in the Palmar Digital Arteries

Huanan Zhang, Gia-Bao Ha, Benjamin Sanchez, Alexandra Boyadzhiev
Hemodynamic Monitoring and Therapy
article

A Wearable Smart Ring for Measuring Bioimpedance in the Palmar Digital Arteries

Huanan Zhang, Gia-Bao Ha, Benjamin Sanchez, Alexandra Boyadzhiev
article en

Abstract

Bioimpedance (BioZ) is a non-invasive and low-cost technology capable of monitoring conductivity rapidly. BioZ holds promise for integration into wearable devices for outpatient monitoring. Here, we propose the integration of BioZ into a smart ring form factor using electrodes coated with poly(3,4-ethylenedioxythiophene) (PEDOT) conductive polymer. PEDOT reduces contact electrode impedance by increasing the effective contact area at the skin-electrode interface and having high ionic conductivity. In this feasibility study, we developed a ring sensor, deposited PEDOT on the electrodes, and compared its capability to record pulsatile BioZ data at the finger against untreated electrodes. We performed electrochemical impedance spectroscopy (EIS) and BioZ measurements. EIS results showed that electrode contact impedance decreased by a factor of 1.2 compared to the untreated electrodes at the relevant frequency. Our results show the capability of our smart ring sensor to detect pulsatile BioZ at the digital arteries.

University of Utah (US)
Affordable and clean energy
Openalex Percentile: Top 58%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.