A Low-Cost Embedded Imaging System for Low-Limb Vascular Metrics Monitoring

Cardiovascular metrics measurement and monitoring have been a critical need worldwide. The main objective of this work is to prototype an embedded imager for cardiovascular metrics monitoring. Utilizing an 850 nm Near-Infrared (NIR) light source and an Infrared (IR) camera, the system leverages the optical properties of human skin to extract Photoplethysmogram (PPG) signals, heart rate, and vascular structure from video data. We tested the system with 10 participants, comparing its heart rate measurements to those obtained from a contact PPG sensor, achieving an accuracy within ±5 bpm. Additionally, using an artificial hand phantom for blood vessel visualization, the system demonstrated a vessel extraction accuracy with an average error of 10.21 % in blood vessel width, confirming the effectiveness of our NIR-enhanced imaging approach.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780688
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low-Cost Embedded Imaging System for Low-Limb Vascular Metrics Monitoring

Wenyao Xu, Huining Li, C.S. Liu, Alexander Gherardi et al.
Advanced X-ray and CT Imaging
article

A Low-Cost Embedded Imaging System for Low-Limb Vascular Metrics Monitoring

Wenyao Xu, Huining Li, C.S. Liu, Alexander Gherardi, Jun Xia
article en

Abstract

Cardiovascular metrics measurement and monitoring have been a critical need worldwide. The main objective of this work is to prototype an embedded imager for cardiovascular metrics monitoring. Utilizing an 850 nm Near-Infrared (NIR) light source and an Infrared (IR) camera, the system leverages the optical properties of human skin to extract Photoplethysmogram (PPG) signals, heart rate, and vascular structure from video data. We tested the system with 10 participants, comparing its heart rate measurements to those obtained from a contact PPG sensor, achieving an accuracy within ±5 bpm. Additionally, using an artificial hand phantom for blood vessel visualization, the system demonstrated a vessel extraction accuracy with an average error of 10.21 % in blood vessel width, confirming the effectiveness of our NIR-enhanced imaging approach.

University at Buffalo, State University of New York (US)
Openalex Percentile: Top 79%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.