Development and Verification of an Electrode for Recording Electrodermal Activity Underwater

Underwater recording of biosignals such as electrodermal activity has the potential to improve our current understanding of diving medicine. However, the deployment is currently limited by the required waterproofing of EDA electrodes. In this work, we showcase the development and verify our design of a new water-tolerant electrode for underwater EDA collection. In time, frequency, and time-frequency domains, our electrode design performs as well as or better than the standard Ag/AgCI electrodes, showing only a small baseline shift when submerged and produced signal differences no larger than those EDA collected at different sites on the same body. Further development is required to establish the longevity of our electrode and the usability in varied other real-world water environments.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780503
Citations
1
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Verification of an Electrode for Recording Electrodermal Activity Underwater

Andrew Peitzsch, Ki H. Chon, Mahdi Pirayesh Shirazi Nejad
1 citations
Water Quality Monitoring Technologies
0.20
article

Development and Verification of an Electrode for Recording Electrodermal Activity Underwater

Andrew Peitzsch, Ki H. Chon, Mahdi Pirayesh Shirazi Nejad
article en
1 citations

Abstract

Underwater recording of biosignals such as electrodermal activity has the potential to improve our current understanding of diving medicine. However, the deployment is currently limited by the required waterproofing of EDA electrodes. In this work, we showcase the development and verify our design of a new water-tolerant electrode for underwater EDA collection. In time, frequency, and time-frequency domains, our electrode design performs as well as or better than the standard Ag/AgCI electrodes, showing only a small baseline shift when submerged and produced signal differences no larger than those EDA collected at different sites on the same body. Further development is required to establish the longevity of our electrode and the usability in varied other real-world water environments.

University of Connecticut (US)
Life below water
Openalex Percentile: Top 43%
Water Quality Monitoring Technologies
0.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.