Exploring Arterial and Venous Oxygenation Separation with Multichannel PPG<sup>*</sup>

State-of-the-art pulse oximeters capture only arterial blood oxygen <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SaO}_{2})$</tex> but not venous blood oxygen <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SvO}_{2})$</tex>. <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex> is crucial for evaluating the body's oxygen utilization, providing essential insights into cardiovascular and respiratory function. <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex> is difficult to measure noninvasively due to the deeper locations and lower pulsatility of the veins compared to the arteries. To explore the possibility of noninvasive assessment of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex>, we hypothesize that reflective photoplethysmography (PPG) measured on the skin surface over a shallow vein, such as the radial vein, captures the pulsatile absorbance from the vein. However, the difficulty lies in the crosstalk in the PPG signals induced by the adjacent artery. To tackle this challenge, we built a multichannel wireless PPG array, applied Laplacian filtering, and proposed a physiologically inspired spatial filtering method to distinguish arterial vs. venous <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathrm{R}$</tex> values, defined as the ratio of the pulsatile absorbance at two different wavelengths, typically red and infrared (IR). The efficacy of our approach is demonstrated through preliminary in vitro and in vivo experiments.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/bsn63547.2024.10780620
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Arterial and Venous Oxygenation Separation with Multichannel PPG*

Philip Tan, Nanshu Lu, Gahee Son, Eric J. Snider et al.
1 citations
Optical Imaging and Spectroscopy Techniques
0.40
article

Exploring Arterial and Venous Oxygenation Separation with Multichannel PPG*

Philip Tan, Nanshu Lu, Gahee Son, Eric J. Snider, Eric Wang, Cristian Colon
article en
1 citations

Abstract

State-of-the-art pulse oximeters capture only arterial blood oxygen <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SaO}_{2})$</tex> but not venous blood oxygen <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SvO}_{2})$</tex>. <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex> is crucial for evaluating the body's oxygen utilization, providing essential insights into cardiovascular and respiratory function. <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex> is difficult to measure noninvasively due to the deeper locations and lower pulsatility of the veins compared to the arteries. To explore the possibility of noninvasive assessment of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SvO}_{2}$</tex>, we hypothesize that reflective photoplethysmography (PPG) measured on the skin surface over a shallow vein, such as the radial vein, captures the pulsatile absorbance from the vein. However, the difficulty lies in the crosstalk in the PPG signals induced by the adjacent artery. To tackle this challenge, we built a multichannel wireless PPG array, applied Laplacian filtering, and proposed a physiologically inspired spatial filtering method to distinguish arterial vs. venous <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathrm{R}$</tex> values, defined as the ratio of the pulsatile absorbance at two different wavelengths, typically red and infrared (IR). The efficacy of our approach is demonstrated through preliminary in vitro and in vivo experiments.

United States Army Institute of Surgical Research (US), The University of Texas at Austin (US)
Army Research Office
Openalex Percentile: Top 32%
Optical Imaging and Spectroscopy Techniques
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.