Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

We demonstrate magnetic anomaly detection (MAD) using an array of 24 commercial induction coil magnetometers with stand-off distances from a pulsed 99.8(3) kA<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\cdot$</tex-math></inline-formula>m<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{2}$</tex-math></inline-formula> magnetic dipole source of 260–1200 m. The sparse array is used to estimate the magnetic dipole location, magnitude, and orientation. We demonstrate how independent component analysis (ICA) improves the accuracy and precision of the magnetometer array when estimating the dipole parameters. Using sensor responses recorded from individual source pulses, we estimate the dipole location to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$29\pm 2$</tex-math></inline-formula> m, the magnitude to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$3\pm 3$</tex-math></inline-formula> kA<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\cdot$</tex-math></inline-formula>m<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{2}$</tex-math></inline-formula>, and dipole orientation error to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$19\pm 0.6^{\circ }$</tex-math></inline-formula>.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2024-12-11
DOI
https://doi.org/10.1109/lsens.2024.3515639
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

W. Junor, Xianjin Yang, Daniel Thrasher, Joonas Iivanainen et al.
1 citations
IEEE Sensors Letters
Atomic and Subatomic Physics Research
0.34
article

Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

W. Junor, Xianjin Yang, Daniel Thrasher, Joonas Iivanainen, Timothy S. Read
article en
1 citations

Abstract

We demonstrate magnetic anomaly detection (MAD) using an array of 24 commercial induction coil magnetometers with stand-off distances from a pulsed 99.8(3) kA<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\cdot$</tex-math></inline-formula>m<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{2}$</tex-math></inline-formula> magnetic dipole source of 260–1200 m. The sparse array is used to estimate the magnetic dipole location, magnitude, and orientation. We demonstrate how independent component analysis (ICA) improves the accuracy and precision of the magnetometer array when estimating the dipole parameters. Using sensor responses recorded from individual source pulses, we estimate the dipole location to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$29\pm 2$</tex-math></inline-formula> m, the magnitude to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$3\pm 3$</tex-math></inline-formula> kA<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\cdot$</tex-math></inline-formula>m<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^{2}$</tex-math></inline-formula>, and dipole orientation error to within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$19\pm 0.6^{\circ }$</tex-math></inline-formula>.

IEEE Sensors LettersVol. 9(2)
Lawrence Livermore National Laboratory (US), Los Alamos National Laboratory (US), Sandia National Laboratories (US)
Affordable and clean energy
Openalex Percentile: Top 38%
Atomic and Subatomic Physics Research
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.