Implementing an AI That Automatically Extracts Standardized Functional Patterns From Wearable Sensor Data

Standardized functional tests (SFTs) are frequently used to quantify a person’s ability to perform activities of daily living (ADLs) against expected values. SFTs provide valuable information to aid a clinician’s understanding of a patient’s status and direction of improvement. Such information may support clinicians when assessing a wide range of conditions such as musculoskeletal or neurological diseases or age-related frailty. If these SFTs could be performed reliably by patients in their own home without supervision, they could track and help to guide rehabilitation. Wearable devices have the potential to collect reliable data from the wearer when performing SFTs. However, the data generated from sensors for long-term recordings of movement can become very large, making it difficult to manually extract movement information with any level of accuracy. Hence, it is important to evaluate whether it is possible to implement an automated system capable of extracting SFT patterns from long-term sensor data without manual data processing. This article describes an artificial neural network (ANN) system that was trained to extract specific SFTs such as the 30-s chair stand test (CST) (30s-CST) and the 40-m fast-paced walk test (40m-FPWT). The resultant model obtained 99.7% accuracy in 30s-CST pattern recognition, 99.3% accuracy in 40m-FPWT pattern recognition, and 97.3% accuracy in detecting false patterns. The system provided an overall accuracy of 98.76% with supervised clinical trial data. The ambulatory data testing phase obtained an overall accuracy of 90.18%. Specifically, it achieved 92.73% accuracy in detecting 30s-CST patterns and 86.67% accuracy in recognizing 40m-FPWT patterns.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-12-11
DOI
https://doi.org/10.1109/jsen.2024.3509021
Primary Topic
Context-Aware Activity Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementing an AI That Automatically Extracts Standardized Functional Patterns From Wearable Sensor Data

Philip Gardiner, Joan Condell, Vini Vijayan, Nigel McKelvey et al.
IEEE Sensors Journal
Context-Aware Activity Recognition Systems
article

Implementing an AI That Automatically Extracts Standardized Functional Patterns From Wearable Sensor Data

Philip Gardiner, Joan Condell, Vini Vijayan, Nigel McKelvey, James Connolly
article en

Abstract

Standardized functional tests (SFTs) are frequently used to quantify a person’s ability to perform activities of daily living (ADLs) against expected values. SFTs provide valuable information to aid a clinician’s understanding of a patient’s status and direction of improvement. Such information may support clinicians when assessing a wide range of conditions such as musculoskeletal or neurological diseases or age-related frailty. If these SFTs could be performed reliably by patients in their own home without supervision, they could track and help to guide rehabilitation. Wearable devices have the potential to collect reliable data from the wearer when performing SFTs. However, the data generated from sensors for long-term recordings of movement can become very large, making it difficult to manually extract movement information with any level of accuracy. Hence, it is important to evaluate whether it is possible to implement an automated system capable of extracting SFT patterns from long-term sensor data without manual data processing. This article describes an artificial neural network (ANN) system that was trained to extract specific SFTs such as the 30-s chair stand test (CST) (30s-CST) and the 40-m fast-paced walk test (40m-FPWT). The resultant model obtained 99.7% accuracy in 30s-CST pattern recognition, 99.3% accuracy in 40m-FPWT pattern recognition, and 97.3% accuracy in detecting false patterns. The system provided an overall accuracy of 98.76% with supervised clinical trial data. The ambulatory data testing phase obtained an overall accuracy of 90.18%. Specifically, it achieved 92.73% accuracy in detecting 30s-CST patterns and 86.67% accuracy in recognizing 40m-FPWT patterns.

IEEE Sensors JournalVol. 25(3)
University of Ulster (GB), Letterkenny Institute of Technology (IE), Altnagelvin Area Hospital (GB), OGT Amenity (Ireland) (IE), Atlantic Technological University (IE)
Openalex Percentile: Top 78%
Context-Aware Activity Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.