MRgRT real-time target localization using foundation models for contour point tracking and promptable mask refinement

<i>Objective</i>. This study aimed to evaluate two real-time target tracking approaches for magnetic resonance imaging (MRI) guided radiotherapy (MRgRT) based on foundation artificial intelligence models.<i>Approach</i>. The first approach used a point-tracking model that propagates points from a reference contour. The second approach used a video-object-segmentation model, based on segment anything model 2 (SAM2). Both approaches were evaluated and compared against each other, inter-observer variability, and a transformer-based image registration model, TransMorph, with and without patient-specific (PS) fine-tuning. The evaluation was carried out on 2D cine MRI datasets from two institutions, containing scans from 33 patients with 8060 labeled frames, with annotations from 2 to 5 observers per frame, totaling 29179 ground truth segmentations. The segmentations produced were assessed using the Dice similarity coefficient (DSC), 50% and 95% Hausdorff distances (HD50 / HD95), and the Euclidean center distance (ECD).<i>Main results</i>. The results showed that the contour tracking (median DSC0.92±0.04and ECD1.9±1.0 mm) and SAM2-based (median DSC0.93±0.03and ECD1.6±1.1 mm) approaches produced target segmentations comparable or superior to TransMorph w/o PS fine-tuning (median DSC0.91±0.07and ECD2.6±1.4 mm) and slightly inferior to TransMorph w/ PS fine-tuning (median DSC0.94±0.03and ECD1.4±0.8 mm). Between the two novel approaches, the one based on SAM2 performed marginally better at a higher computational cost (inference times 92 ms for contour tracking and 109 ms for SAM2). Both approaches and TransMorph w/ PS fine-tuning exceeded inter-observer variability (median DSC0.90±0.06and ECD1.7±0.7 mm).<i>Significance</i>. This study demonstrates the potential of foundation models to achieve high-quality real-time target tracking in MRgRT, offering performance that matches state-of-the-art methods without requiring PS fine-tuning.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-11
DOI
https://doi.org/10.1088/1361-6560/ad9dad
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRgRT real-time target localization using foundation models for contour point tracking and promptable mask refinement

Stefanie Corradini, Sebastian Marschner, Claus Belka, Christopher Kurz et al.
2 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
1.22
article

MRgRT real-time target localization using foundation models for contour point tracking and promptable mask refinement

Stefanie Corradini, Sebastian Marschner, Claus Belka, Christopher Kurz, T. Blöcker, Marco Riboldi, Guillaume Landry, M. Palacios, Elia Lombardo
article en
2 citations

Abstract

<i>Objective</i>. This study aimed to evaluate two real-time target tracking approaches for magnetic resonance imaging (MRI) guided radiotherapy (MRgRT) based on foundation artificial intelligence models.<i>Approach</i>. The first approach used a point-tracking model that propagates points from a reference contour. The second approach used a video-object-segmentation model, based on segment anything model 2 (SAM2). Both approaches were evaluated and compared against each other, inter-observer variability, and a transformer-based image registration model, TransMorph, with and without patient-specific (PS) fine-tuning. The evaluation was carried out on 2D cine MRI datasets from two institutions, containing scans from 33 patients with 8060 labeled frames, with annotations from 2 to 5 observers per frame, totaling 29179 ground truth segmentations. The segmentations produced were assessed using the Dice similarity coefficient (DSC), 50% and 95% Hausdorff distances (HD50 / HD95), and the Euclidean center distance (ECD).<i>Main results</i>. The results showed that the contour tracking (median DSC0.92±0.04and ECD1.9±1.0 mm) and SAM2-based (median DSC0.93±0.03and ECD1.6±1.1 mm) approaches produced target segmentations comparable or superior to TransMorph w/o PS fine-tuning (median DSC0.91±0.07and ECD2.6±1.4 mm) and slightly inferior to TransMorph w/ PS fine-tuning (median DSC0.94±0.03and ECD1.4±0.8 mm). Between the two novel approaches, the one based on SAM2 performed marginally better at a higher computational cost (inference times 92 ms for contour tracking and 109 ms for SAM2). Both approaches and TransMorph w/ PS fine-tuning exceeded inter-observer variability (median DSC0.90±0.06and ECD1.7±0.7 mm).<i>Significance</i>. This study demonstrates the potential of foundation models to achieve high-quality real-time target tracking in MRgRT, offering performance that matches state-of-the-art methods without requiring PS fine-tuning.

Physics in Medicine and BiologyVol. 70(1)
LMU Klinikum (DE), Amsterdam Neuroscience (NL), München Klinik (DE), German Centre for Cardiovascular Research (DE), Ludwig-Maximilians-Universität München (DE), Vrije Universiteit Amsterdam (NL)
Openalex Percentile: Top 19%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.