Validation of the generalized stochastic microdosimetric model (GSM <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> ) over a broad range of LET and par

<i>Objective</i>. The present work shows the first extensive validation of the<i>generalized stochastic microdosimetric model</i>(GSM<sup>2</sup>). This mechanistic and probabilistic model is trained and tested over cell survival experiments conducted with two cell lines (H460 and H1437), three different types of radiation (protons, helium, and carbon ions), spanning a very broad LET range from1 keVμm-1up to more than300 keVμm-1. Currently, the existing mechanistic radiation biophysical models show some limitations in describing cell killing without the addition of ad hoc corrections, especially in the high-LET regime, where the overkill effect is observed.<i>Approach</i>. The experimental irradiation conditions have been accurately reproduced with Monte Carlo simulations using the GEANT4-based TOPAS computational toolkit. We show the main and unique features of GSM2, i.e. how it can predict the biological response by considering the full information on the stochasticity of radiation through the microdosimetric spectrum, which is supposed to be the best descriptor of radiation quality.<i>Main results</i>. Well-matching results for different biological endpoints with the natural presence of the overkill effect fully display the predictive power of GSM<sup>2</sup>.<i>Significance</i>. This study shows the complete generality and flexibility of GSM<sup>2</sup>and its ability to successfully predict the cell survival probability from very different particle radiation fields. Consequently, we demonstrate the dependence of the relative biological effectiveness on the whole microdosimetric spectrum, which fully includes the stochasticity inherently given by radiation-matter interaction.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-11
DOI
https://doi.org/10.1088/1361-6560/ad9dab
Citations
4
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of the generalized stochastic microdosimetric model (GSM <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> ) over a broad range of LET and par

Emanuele Scifoni, Gianluca Lattanzi, Francesco Cordoni, Marta Missiaggia et al.
4 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
1.68
article

Validation of the generalized stochastic microdosimetric model (GSM <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> ) over a broad range of LET and par

Emanuele Scifoni, Gianluca Lattanzi, Francesco Cordoni, Marta Missiaggia, Chiara La Tessa, David R. Grosshans, Lawrence F. Bronk, Giorgio Cartechini, Marco Battestini, Fada Guan, Pallavi Rai, Giulio Bordieri
article en
4 citations

Abstract

<i>Objective</i>. The present work shows the first extensive validation of the<i>generalized stochastic microdosimetric model</i>(GSM<sup>2</sup>). This mechanistic and probabilistic model is trained and tested over cell survival experiments conducted with two cell lines (H460 and H1437), three different types of radiation (protons, helium, and carbon ions), spanning a very broad LET range from1 keVμm-1up to more than300 keVμm-1. Currently, the existing mechanistic radiation biophysical models show some limitations in describing cell killing without the addition of ad hoc corrections, especially in the high-LET regime, where the overkill effect is observed.<i>Approach</i>. The experimental irradiation conditions have been accurately reproduced with Monte Carlo simulations using the GEANT4-based TOPAS computational toolkit. We show the main and unique features of GSM2, i.e. how it can predict the biological response by considering the full information on the stochasticity of radiation through the microdosimetric spectrum, which is supposed to be the best descriptor of radiation quality.<i>Main results</i>. Well-matching results for different biological endpoints with the natural presence of the overkill effect fully display the predictive power of GSM<sup>2</sup>.<i>Significance</i>. This study shows the complete generality and flexibility of GSM<sup>2</sup>and its ability to successfully predict the cell survival probability from very different particle radiation fields. Consequently, we demonstrate the dependence of the relative biological effectiveness on the whole microdosimetric spectrum, which fully includes the stochasticity inherently given by radiation-matter interaction.

Physics in Medicine and BiologyVol. 70(1)
The University of Texas MD Anderson Cancer Center (US), University of Miami (US), University of Trento (IT), Maastricht University Medical Centre (NL), Yale University (US), Istituto Nazionale di Fisica Nucleare, Trento Institute for Fundamental Physics And Applications (IT), Maastro Clinic (NL)
European Commission, Commissione Scientifica Nazionale 5, Instituto Nazionale di Fisica Nucleare
Openalex Percentile: Top 14%
Radiation Therapy and Dosimetry
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.