New inlet duct arrangements for grain aeration in a small-scale silo: Computational simulation and experimental validation

The arrangement of air inlet ducts is a crucial factor influencing the temperature distribution within grain storage systems. Poorly designed ducts can result in uneven temperature distribution throughout the grain bulk, leading to localized conditions that promote fungal and insect growth, while also increasing the power consumption of the fan needed for aeration. This study aimed to evaluate the temperature distribution within bulk rough rice during aeration, using both numerical simulations and experimental methods, for three innovative inlet air duct arrangements -E, F, and H-each resembling the respective letter's shape. The study was conducted on a scaled-down model of a one-fourteenth real-size on-farm silo. Temperature data were collected at various locations within the grain bed, and the simulation outcomes were validated by comparing them to the experimental data. The results indicate that, for all three air inlet arrangements, the temperature distribution in both cross-sectional planes (parallel and perpendicular to the airflow direction) was uniform by the end of the aeration process. The time required to reach a temperature of 15.5 °C in both planes was approximately the same, highlighting the effective performance of these arrangements in different orientations. Among the duct arrangements in the experimental silo, the F-duct arrangement demonstrated superior ventilation performance, achieving the target temperature at least %25 faster than the E and H arrangements. The higher efficiency is attributed to its larger volumetric heat transfer coefficient. The H duct arrangement, however, offers other advantages, including a pressure drop that is at least 30% lower and a minimum 17% reduction in power consumption within the storage bed compared to the F and E duct configurations. The numerical simulations closely aligned with the experimental data. The relative mean error values for volume flow rates of 0.0064, 0.014, and 0.018 m³.s − 1 ranged between 2 and 3.53%, 2.77–4.98%, and 2.42–8.52%, respectively. These results confirm the model's accuracy and underscore its potential as a valuable tool for optimizing silo inlet duct designs. • Innovative inlet air duct designs (E, F, H) were developed to enhance aeration performance in on-farm grain silos. • F-duct configuration offers better ventilation performance and faster air temperature equilibrium with the stored grain. • H-duct configuration minimizes pressure drop and require smaller fan for aeration. • The H-duct configuration in a real silo achieves 21% and 17% energy savings compared to E and F ducts, respectively.

Authors

Institutions

Publication Details

Journal
Journal of Stored Products Research
Published
2024-12-12
DOI
https://doi.org/10.1016/j.jspr.2024.102511
Citations
3
Primary Topic
Granular flow and fluidized beds
Type
article
Field-Weighted Citation Impact
1.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New inlet duct arrangements for grain aeration in a small-scale silo: Computational simulation and experimental validation

Dariush Zare, Kamran Maleki-Majd, Naser Razavizadeh
3 citations
Journal of Stored Products Research
Granular flow and fluidized beds
1.12
article

New inlet duct arrangements for grain aeration in a small-scale silo: Computational simulation and experimental validation

Dariush Zare, Kamran Maleki-Majd, Naser Razavizadeh
article en
3 citations

Abstract

The arrangement of air inlet ducts is a crucial factor influencing the temperature distribution within grain storage systems. Poorly designed ducts can result in uneven temperature distribution throughout the grain bulk, leading to localized conditions that promote fungal and insect growth, while also increasing the power consumption of the fan needed for aeration. This study aimed to evaluate the temperature distribution within bulk rough rice during aeration, using both numerical simulations and experimental methods, for three innovative inlet air duct arrangements -E, F, and H-each resembling the respective letter's shape. The study was conducted on a scaled-down model of a one-fourteenth real-size on-farm silo. Temperature data were collected at various locations within the grain bed, and the simulation outcomes were validated by comparing them to the experimental data. The results indicate that, for all three air inlet arrangements, the temperature distribution in both cross-sectional planes (parallel and perpendicular to the airflow direction) was uniform by the end of the aeration process. The time required to reach a temperature of 15.5 °C in both planes was approximately the same, highlighting the effective performance of these arrangements in different orientations. Among the duct arrangements in the experimental silo, the F-duct arrangement demonstrated superior ventilation performance, achieving the target temperature at least %25 faster than the E and H arrangements. The higher efficiency is attributed to its larger volumetric heat transfer coefficient. The H duct arrangement, however, offers other advantages, including a pressure drop that is at least 30% lower and a minimum 17% reduction in power consumption within the storage bed compared to the F and E duct configurations. The numerical simulations closely aligned with the experimental data. The relative mean error values for volume flow rates of 0.0064, 0.014, and 0.018 m³.s − 1 ranged between 2 and 3.53%, 2.77–4.98%, and 2.42–8.52%, respectively. These results confirm the model's accuracy and underscore its potential as a valuable tool for optimizing silo inlet duct designs. • Innovative inlet air duct designs (E, F, H) were developed to enhance aeration performance in on-farm grain silos. • F-duct configuration offers better ventilation performance and faster air temperature equilibrium with the stored grain. • H-duct configuration minimizes pressure drop and require smaller fan for aeration. • The H-duct configuration in a real silo achieves 21% and 17% energy savings compared to E and F ducts, respectively.

Journal of Stored Products ResearchVol. 111
University of Tasmania (AU), Shiraz University (IR)
Openalex Percentile: Top 24%
Granular flow and fluidized beds
1.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.