Elastance-based nonlinear dynamical controller synthesis for the in-vitro cardiovascular circulatory system: A backstepping approach

This paper investigates the application of a nonlinear system-dependent and system-independent dynamical backstepping (DBST) controller on a cardiovascular circulatory simulator (CCS) with non-triangular affine dynamics for the first time in literature. That is, this study introduces several novel contributions to the field, including the enhancement of cardiac output and physiological fidelity while addressing the limitations of existing control methods. Additionally, we present a comparative performance evaluation of feedback linearization (FBL) and the developed DBST controller with respect to integral squared error (ISE), integral absolute error (IAE), and integral time absolute error (ITAE), offering new insights into each control technique’s error minimization capabilities and overall system performance effectiveness. Furthermore, we pioneer the use of Monte-Carlo (MC) simulations as a reliable in-vitro alternative to clinical trials for controller performance assessment under intra- and inter-patient parameter variations. This innovative approach overcomes the limitations of in-vivo evaluations, enabling the analysis of crucial factors such as signal energy and reference tracking error value. Our results, supported by both MC simulations, demonstrate the complete superiority of the DBST controller over FBL in terms of error reduction and adaptability due to patient-to-patient variability, thus validating its potential for practical applications in cardiovascular circulatory systems.

Authors

Institutions

Publication Details

Journal
Journal of Vibration and Control
Published
2024-12-10
DOI
https://doi.org/10.1177/10775463241305679
Citations
1
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elastance-based nonlinear dynamical controller synthesis for the in-vitro cardiovascular circulatory system: A backstepping approach

Seyed Jalil Sadati, Paolo Castaldi, Aliakbar Hedayati, Hasan Abbasi Nozari et al.
1 citations
Journal of Vibration and Control
Mechanical Circulatory Support Devices
0.18
article

Elastance-based nonlinear dynamical controller synthesis for the in-vitro cardiovascular circulatory system: A backstepping approach

Seyed Jalil Sadati, Paolo Castaldi, Aliakbar Hedayati, Hasan Abbasi Nozari, Erfan Noshad
article en
1 citations

Abstract

This paper investigates the application of a nonlinear system-dependent and system-independent dynamical backstepping (DBST) controller on a cardiovascular circulatory simulator (CCS) with non-triangular affine dynamics for the first time in literature. That is, this study introduces several novel contributions to the field, including the enhancement of cardiac output and physiological fidelity while addressing the limitations of existing control methods. Additionally, we present a comparative performance evaluation of feedback linearization (FBL) and the developed DBST controller with respect to integral squared error (ISE), integral absolute error (IAE), and integral time absolute error (ITAE), offering new insights into each control technique’s error minimization capabilities and overall system performance effectiveness. Furthermore, we pioneer the use of Monte-Carlo (MC) simulations as a reliable in-vitro alternative to clinical trials for controller performance assessment under intra- and inter-patient parameter variations. This innovative approach overcomes the limitations of in-vivo evaluations, enabling the analysis of crucial factors such as signal energy and reference tracking error value. Our results, supported by both MC simulations, demonstrate the complete superiority of the DBST controller over FBL in terms of error reduction and adaptability due to patient-to-patient variability, thus validating its potential for practical applications in cardiovascular circulatory systems.

Journal of Vibration and ControlVol. 32(5-6)
Babol Noshirvani University of Technology (IR), University of Bologna (IT)
Openalex Percentile: Top 50%
Mechanical Circulatory Support Devices
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.