Fluorescent Reporter‐Based Fiber Optic Probe for Continuous Detection of Antibodies

Measurement of antibody and antibody fusion protein concentration is vital for process development and manufacturing. Continuous, in-line monitoring of antibody concentration could be useful in a variety of applications, such as controlling the loading of protein A columns to prevent breakthrough, monitoring bioreactor titer, and detecting leaks past ultrafiltration/diafiltration membranes. Molecule-specific monitoring techniques are advantageous for antibody detection in cell culture fluid in the presence of complex process impurities. Here we report a continuous in-line, real-time IgG monitoring platform using a fiber-optic biosensor with a replaceable sensor tip covalently functionalized with a fluor-labeled protein consisting of a pentamer of the Z domain (a more stable form of the B domain) of protein A. The sensor demonstrates concentration-dependent fluorescence enhancement in the presence of human IgG (0.01-0.75 g/L), with consistent signals during five runs each with 1 and 0.1 g/L IgG, and maintains its specificity in the presence of Chinese hamster ovary (CHO) cell culture fluid. A 5% breakthrough of a typical 10 g/L load would be detected in less than 20 s in a flowing stream emerging from a protein A column without prior sample preparation. This sensor platform may be suitable for monitoring IgG and fragment, crystallizable (Fc) fusion proteins in diverse upstream and downstream bioprocess applications.

Authors

Institutions

Publication Details

Journal
Biotechnology and Bioengineering
Published
2024-12-10
DOI
https://doi.org/10.1002/bit.28900
Primary Topic
Viral Infectious Diseases and Gene Expression in Insects
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluorescent Reporter‐Based Fiber Optic Probe for Continuous Detection of Antibodies

Suman Nandy, Richard C. Willson, Vijay Maranholkar, Binh Vu et al.
Biotechnology and Bioengineering
Viral Infectious Diseases and Gene Expression in Insects
article

Fluorescent Reporter‐Based Fiber Optic Probe for Continuous Detection of Antibodies

Suman Nandy, Richard C. Willson, Vijay Maranholkar, Binh Vu, Katerina Kourentzi, Atul Goyal
article en

Abstract

Measurement of antibody and antibody fusion protein concentration is vital for process development and manufacturing. Continuous, in-line monitoring of antibody concentration could be useful in a variety of applications, such as controlling the loading of protein A columns to prevent breakthrough, monitoring bioreactor titer, and detecting leaks past ultrafiltration/diafiltration membranes. Molecule-specific monitoring techniques are advantageous for antibody detection in cell culture fluid in the presence of complex process impurities. Here we report a continuous in-line, real-time IgG monitoring platform using a fiber-optic biosensor with a replaceable sensor tip covalently functionalized with a fluor-labeled protein consisting of a pentamer of the Z domain (a more stable form of the B domain) of protein A. The sensor demonstrates concentration-dependent fluorescence enhancement in the presence of human IgG (0.01-0.75 g/L), with consistent signals during five runs each with 1 and 0.1 g/L IgG, and maintains its specificity in the presence of Chinese hamster ovary (CHO) cell culture fluid. A 5% breakthrough of a typical 10 g/L load would be detected in less than 20 s in a flowing stream emerging from a protein A column without prior sample preparation. This sensor platform may be suitable for monitoring IgG and fragment, crystallizable (Fc) fusion proteins in diverse upstream and downstream bioprocess applications.

Biotechnology and BioengineeringVol. 122(3)
Merck & Co., Inc., Rahway, NJ, USA (United States) (US), Pfizer (United States) (US), University of Houston (US), Tecnológico de Monterrey (MX)
Amgen, AstraZeneca, GlaxoSmithKline, North Carolina State University, Golden LEAF Foundation, National Institutes of Health, University of Texas MD Anderson Cancer Center, National Institute for Innovation in Manufacturing Biopharmaceuticals
Openalex Percentile: Top 80%
Viral Infectious Diseases and Gene Expression in Insects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.