Techno-economic optimization and sensitivity analysis of off-grid hybrid renewable energy systems: A case study for sustainable energy solutions in rural India

• Novel integration of hydrogen storage and battery systems in an optimized hybrid renewable energy system (HRES) for off-grid rural electrification. • First comprehensive techno-economic assessment of HRES using solid waste biomass, solar, and wind energy sources for Indian communities. • Unique application of sensitivity analysis to evaluate the impact of economic variables on system performance and renewable energy utilization. • Innovative hybrid system configuration achieving 100% renewable energy fraction with minimal environmental impact and optimized energy cost. • New insights into the role of hydrogen as a sustainable energy storage solution within standalone HRES for enhanced energy reliability. In the twenty-first century, global energy consumption is rapidly increasing, particularly in emerging nations, hastening the depletion of fossil fuel reserves and emphasizing the vital need for sustainable and renewable energy sources. This study aims to analyze hybrid renewable energy systems (HRESs) that use solid waste to generate power, focusing on difficulties linked to intermittent renewable sources using a techno-economic framework. Employing the HOMER Pro software, prefeasibility analysis is performed to meet the energy needs of an Indian community. System architecture optimization depends on factors like minimizing net present cost (NPC), achieving the lowest cost of energy (COE), and maximizing renewable source utilization. This study evaluates the technical, economic, and environmental feasibility of a hybrid renewable energy system (HRES) comprising a 400-kW solar photovoltaic (PV) array, a 100-kW wind turbine (WT), a 100-kW electrolyzer, 918 number of 12V batteries, a 200-kW converter, a 200-kW reformer, and a 15-kg hydrogen tank (H-tank). This optimal configuration has the lowest NPC of $26.8 million and COE of $4.32 per kilowatt-hour, and a Renewable Fraction (RF) of 100%. It can provide a dependable power supply and satisfy 94% of the daily onsite load demand, which is 1080 kilowatt-hours per day. The required electricity is sourced to load demand entirely from renewable energy at the given location. Additionally, the study highlights the benefits of HRES in solid waste management, considering technological advancements and regulatory frameworks. Furthermore, sensitivity analysis is conducted to measure economic factors that influence HRES, accounting for fluctuations in load demand, project lifespan, diesel fuel costs and interest rates. Installing an HRES custom-made to the local environmental conditions would provide a long-lasting, reliable, and cost-effective energy source. The results show that the optimal HRES system performs well and is a viable option for sustainable electrification in rural communities.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-12-11
DOI
https://doi.org/10.1016/j.rineng.2024.103674
Citations
42
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
7.12

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techno-economic optimization and sensitivity analysis of off-grid hybrid renewable energy systems: A case study for sustainable energy solutions in rural India

Pasala Gopi, Mohit Bajaj, Vojtěch Blažek, Sunil Kumar P et al.
42 citations
Results in Engineering
Hybrid Renewable Energy Systems
7.12
article

Techno-economic optimization and sensitivity analysis of off-grid hybrid renewable energy systems: A case study for sustainable energy solutions in rural India

Pasala Gopi, Mohit Bajaj, Vojtěch Blažek, Sunil Kumar P, Ch. Naga Sai Kalyan, Pujari Harish Kumar, N. Chinna Alluraiah
article en
42 citations

Abstract

• Novel integration of hydrogen storage and battery systems in an optimized hybrid renewable energy system (HRES) for off-grid rural electrification. • First comprehensive techno-economic assessment of HRES using solid waste biomass, solar, and wind energy sources for Indian communities. • Unique application of sensitivity analysis to evaluate the impact of economic variables on system performance and renewable energy utilization. • Innovative hybrid system configuration achieving 100% renewable energy fraction with minimal environmental impact and optimized energy cost. • New insights into the role of hydrogen as a sustainable energy storage solution within standalone HRES for enhanced energy reliability. In the twenty-first century, global energy consumption is rapidly increasing, particularly in emerging nations, hastening the depletion of fossil fuel reserves and emphasizing the vital need for sustainable and renewable energy sources. This study aims to analyze hybrid renewable energy systems (HRESs) that use solid waste to generate power, focusing on difficulties linked to intermittent renewable sources using a techno-economic framework. Employing the HOMER Pro software, prefeasibility analysis is performed to meet the energy needs of an Indian community. System architecture optimization depends on factors like minimizing net present cost (NPC), achieving the lowest cost of energy (COE), and maximizing renewable source utilization. This study evaluates the technical, economic, and environmental feasibility of a hybrid renewable energy system (HRES) comprising a 400-kW solar photovoltaic (PV) array, a 100-kW wind turbine (WT), a 100-kW electrolyzer, 918 number of 12V batteries, a 200-kW converter, a 200-kW reformer, and a 15-kg hydrogen tank (H-tank). This optimal configuration has the lowest NPC of $26.8 million and COE of $4.32 per kilowatt-hour, and a Renewable Fraction (RF) of 100%. It can provide a dependable power supply and satisfy 94% of the daily onsite load demand, which is 1080 kilowatt-hours per day. The required electricity is sourced to load demand entirely from renewable energy at the given location. Additionally, the study highlights the benefits of HRES in solid waste management, considering technological advancements and regulatory frameworks. Furthermore, sensitivity analysis is conducted to measure economic factors that influence HRES, accounting for fluctuations in load demand, project lifespan, diesel fuel costs and interest rates. Installing an HRES custom-made to the local environmental conditions would provide a long-lasting, reliable, and cost-effective energy source. The results show that the optimal HRES system performs well and is a viable option for sustainable electrification in rural communities.

Results in EngineeringVol. 25
Al-Ahliyya Amman University (JO), VSB - Technical University of Ostrava (CZ), Guntur Medical College (IN), Annamalai University (IN), Institute of Wood Science and Technology (IN), University of Business and Technology (SA), Graphic Era University (IN)
European Commission, Ministerstvo Školství, Mládeže a Tělovýchovy, Ministerstvo Životního Prostředí
Openalex Percentile: Top 3%
Hybrid Renewable Energy Systems
7.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.