Remodeling of Colonic Self‐Expandable Nitinol Stent Using Low Power Argon Plasma Coagulation: A Brief Report

Approximately 10%–40% of patients with colorectal cancer, especially those with left side or rectosigmoid cancer, debut with an acute bowel obstruction, and the use of self-expandable metal stents has increasingly become a valid alternative to emergency surgery, primarily in the palliative setting [1]. However, there are a few situations in which colonic stenting may be less effective, such as colonic flexures or rectum resulting in a higher risk of migration or patient's intolerance. In this case report, we present a colonic stenting in metastatic cancer, where the stent caused rectal discomfort that has been effectively managed by the use of argon plasma coagulation (APC) to trim the distal portion of the stent with a lower power than usually applied. A non-resectable rectosigmoid malignant stenosis in a 75-year-old man was successfully managed by placing an uncovered single-wire self-expandable Nitinol stent. We intentionally left ~15 mm of stent distal to the stenosis to prevent pressure decubitus on the healthy wall immediately downstream of the distal end of the neoplasm, precisely at the rectosigmoid junction. A follow-up endoscopy performed a few weeks later, confirmed the successful resolution of the stenosis although with a slight distal stent displacement. The patient reported normal bowel movements but experienced remarkable discomfort in the rectal area. This pain intensified in a few months and became poorly tolerated by the patient. Thus, a new rectosigmoidoscopy was performed and it evidenced a considerable contact area between the distal portion of the stent and the rectal wall. We decided to cut a distal portion of the stent using APC technique. We employed the ERBE VIO 200-D, set at a power of 50 W and a flow rate of 2 L/min, to perform the cutting was performed first sagittally, then longitudinally near the boundary with the neoplasm (Figure 1). Some fragments were removed with forceps as foreign bodies, while others remained in the rectum, and their softness facilitated their spontaneous expulsion. The procedure was well-tolerated by the patient without any complications (Figure 2). Subsequently, the patient's previously reported rectal symptoms disappeared and his bowel transit was always regular without tenesmus or rectal discomfort until his death 12 months after the stent implantation due to tumor cachexia. The trimming of the distal portion of self-expandable metal stents has been previously described, primarily for biliary types [2]. Few cases have been reported involving stents rectosigmoid malignant stenosis [3-7], which were made of cobalt-chromium-nickel-molybdenum alloys or nitinol (nickel-titanium): Nitinol is a member of the shape-memory alloy, which, in turn, are part of the even broader category of Smart Materials. The particular feature of these materials is the ability to change their properties when subjected to specific stimuli due to their intrinsic characteristics. Furthermore, few reports evidenced the use of YAG laser in this biliary context [8]. In literature, the APC settings were used with a power ranging from 70 to 100 W (in the last ablation setting of nouvelle VIO 3) and with 0.8 to 2 L/min for flow. In our case the nitinol stent that we easily trimmed by a power of 50 W with a flow of 2 L/min. We believe that this cut setting is safer, more precise, and controlled even if it is slower compared to the above-mentioned techniques. In particular, in our case, no thermal injury of the mucosa occurred (Video S1). The partial trimming of the distal end of a self-expanding nitinol stent implanted in rectosigmoid stenosis is simple and safe, as previously described in the literature. Nowadays, the majority of colonic stents are made up of a single-wire nitinol alloy, and they are easily moldable by APC. Furthermore, it is not mandatory to remove the fragments by forceps, as they are spontaneously expelled without any complications. In conclusion, this is the first report on the use of APC for stent trimming at lower power setting. Further reports are necessary to confirm and validate the efficacy and safety of this procedure with this novel setting. Open access publishing facilitated by Universita degli Studi di Pavia, as part of the Wiley-CRUI-CARE agreement. Patient signed the informed consent for the colonoscopies and for the use of his data for scientific purpose. CARE guidelines were followed for this case report. Institutional ethical committee approval was not required. The authors declare no conflicts of interest. Video S1. Trimming of the stent. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Authors

Institutions

Publication Details

Journal
JGH Open
Published
2024-12-01
DOI
https://doi.org/10.1002/jgh3.70076
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remodeling of Colonic Self‐Expandable Nitinol Stent Using Low Power Argon Plasma Coagulation: A Brief Report

Antonio Cilona, Davide Scalvini, Andrea A. Anderloni, S. Bargiggia et al.
JGH Open
Esophageal and GI Pathology
article

Remodeling of Colonic Self‐Expandable Nitinol Stent Using Low Power Argon Plasma Coagulation: A Brief Report

Antonio Cilona, Davide Scalvini, Andrea A. Anderloni, S. Bargiggia, Nur Fardowza, Patrizia Busseni
article en

Abstract

Approximately 10%–40% of patients with colorectal cancer, especially those with left side or rectosigmoid cancer, debut with an acute bowel obstruction, and the use of self-expandable metal stents has increasingly become a valid alternative to emergency surgery, primarily in the palliative setting [1]. However, there are a few situations in which colonic stenting may be less effective, such as colonic flexures or rectum resulting in a higher risk of migration or patient's intolerance. In this case report, we present a colonic stenting in metastatic cancer, where the stent caused rectal discomfort that has been effectively managed by the use of argon plasma coagulation (APC) to trim the distal portion of the stent with a lower power than usually applied. A non-resectable rectosigmoid malignant stenosis in a 75-year-old man was successfully managed by placing an uncovered single-wire self-expandable Nitinol stent. We intentionally left ~15 mm of stent distal to the stenosis to prevent pressure decubitus on the healthy wall immediately downstream of the distal end of the neoplasm, precisely at the rectosigmoid junction. A follow-up endoscopy performed a few weeks later, confirmed the successful resolution of the stenosis although with a slight distal stent displacement. The patient reported normal bowel movements but experienced remarkable discomfort in the rectal area. This pain intensified in a few months and became poorly tolerated by the patient. Thus, a new rectosigmoidoscopy was performed and it evidenced a considerable contact area between the distal portion of the stent and the rectal wall. We decided to cut a distal portion of the stent using APC technique. We employed the ERBE VIO 200-D, set at a power of 50 W and a flow rate of 2 L/min, to perform the cutting was performed first sagittally, then longitudinally near the boundary with the neoplasm (Figure 1). Some fragments were removed with forceps as foreign bodies, while others remained in the rectum, and their softness facilitated their spontaneous expulsion. The procedure was well-tolerated by the patient without any complications (Figure 2). Subsequently, the patient's previously reported rectal symptoms disappeared and his bowel transit was always regular without tenesmus or rectal discomfort until his death 12 months after the stent implantation due to tumor cachexia. The trimming of the distal portion of self-expandable metal stents has been previously described, primarily for biliary types [2]. Few cases have been reported involving stents rectosigmoid malignant stenosis [3-7], which were made of cobalt-chromium-nickel-molybdenum alloys or nitinol (nickel-titanium): Nitinol is a member of the shape-memory alloy, which, in turn, are part of the even broader category of Smart Materials. The particular feature of these materials is the ability to change their properties when subjected to specific stimuli due to their intrinsic characteristics. Furthermore, few reports evidenced the use of YAG laser in this biliary context [8]. In literature, the APC settings were used with a power ranging from 70 to 100 W (in the last ablation setting of nouvelle VIO 3) and with 0.8 to 2 L/min for flow. In our case the nitinol stent that we easily trimmed by a power of 50 W with a flow of 2 L/min. We believe that this cut setting is safer, more precise, and controlled even if it is slower compared to the above-mentioned techniques. In particular, in our case, no thermal injury of the mucosa occurred (Video S1). The partial trimming of the distal end of a self-expanding nitinol stent implanted in rectosigmoid stenosis is simple and safe, as previously described in the literature. Nowadays, the majority of colonic stents are made up of a single-wire nitinol alloy, and they are easily moldable by APC. Furthermore, it is not mandatory to remove the fragments by forceps, as they are spontaneously expelled without any complications. In conclusion, this is the first report on the use of APC for stent trimming at lower power setting. Further reports are necessary to confirm and validate the efficacy and safety of this procedure with this novel setting. Open access publishing facilitated by Universita degli Studi di Pavia, as part of the Wiley-CRUI-CARE agreement. Patient signed the informed consent for the colonoscopies and for the use of his data for scientific purpose. CARE guidelines were followed for this case report. Institutional ethical committee approval was not required. The authors declare no conflicts of interest. Video S1. Trimming of the stent. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

JGH OpenVol. 8(12)
University of Pavia (IT), Ospedale San Carlo (IT), Policlinico San Matteo Fondazione (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Openalex Percentile: Top 58%
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.