Strength of bending concrete filled steel elements of improved design

An improved design of concrete filled steel tube element of rectangular cross-section subjected to bending has been proposed, which has greater strength and requires significantly greater energy consumption for destruction compared to known analogues. To test the effectiveness of the proposed design, experimental studies were carried out on the strength of normal sections and the beam rigidity of concrete filled steel tube beams under four-point bending. Research has shown that by simultaneously strengthening the compressed and tensile zones, it was possible to increase the strength of normal sections of beams. The increase in strength of beams of the improved design averaged 42%. The rigidity of non-reinforced concrete filled steel tube beams turned out to be significantly higher compared to beams without filling the steel pipe with concrete. In the improved beams, the stiffness was still approximately 20% higher. The results of comparing the calculated strength of concrete filled steel tube beams using the limit force method with experimental data indicate their satisfactory agreement.

Authors

Institutions

Publication Details

Journal
Building and reconstruction
Published
2024-12-11
DOI
https://doi.org/10.33979/2073-7416-2024-116-6-37-47
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strength of bending concrete filled steel elements of improved design

Vladimir Rimshin, M. A. Likhidko, M. A. Astafeva, А Л Кришан et al.
1 citations
Building and reconstruction
Structural Load-Bearing Analysis
0.26
article

Strength of bending concrete filled steel elements of improved design

Vladimir Rimshin, M. A. Likhidko, M. A. Astafeva, А Л Кришан, Vladimir Kolesnikov
article en
1 citations

Abstract

An improved design of concrete filled steel tube element of rectangular cross-section subjected to bending has been proposed, which has greater strength and requires significantly greater energy consumption for destruction compared to known analogues. To test the effectiveness of the proposed design, experimental studies were carried out on the strength of normal sections and the beam rigidity of concrete filled steel tube beams under four-point bending. Research has shown that by simultaneously strengthening the compressed and tensile zones, it was possible to increase the strength of normal sections of beams. The increase in strength of beams of the improved design averaged 42%. The rigidity of non-reinforced concrete filled steel tube beams turned out to be significantly higher compared to beams without filling the steel pipe with concrete. In the improved beams, the stiffness was still approximately 20% higher. The results of comparing the calculated strength of concrete filled steel tube beams using the limit force method with experimental data indicate their satisfactory agreement.

Building and reconstruction(6)
Nosov Magnitogorsk State Technical University (RU), Russian Academy of Architecture and Construction Sciences (RU)
Affordable and clean energy
Openalex Percentile: Top 42%
Structural Load-Bearing Analysis
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.