Biomimetic Strategies of Slip Sensing, Perception, and Protection in Prosthetic Hand Grasp

This study develops biomimetic strategies for slip prevention in prosthetic hand grasps. The biomimetic system is driven by a novel slip sensor, followed by slip perception and preventive control. Here, we show that biologically inspired sensorimotor pathways can be restored between the prosthetic hand and users. A Ruffini endings-like slip sensor is used to detect shear forces and identify slip events directly. The slip information and grip force are encoded into a bi-state sensory coding that evokes vibration and buzz tactile sensations in subjects with transcutaneous electrical nerve stimulation (TENS). Subjects perceive slip events under various conditions based on the vibration sensation and voluntarily adjust grip force to prevent further slipping. Additionally, short-latency compensation for grip force is also implemented using a neuromorphic reflex pathway. The reflex loop includes a sensory neuron and interneurons to adjust the activations of antagonistic muscles reciprocally. The slip prevention system is tested in five able-bodied subjects and two transradial amputees with and without reflex compensation. A psychophysical test for perception reveals that the slip can be detected effectively, with a success accuracy of 96.57%. A slip protection test indicates that reflex compensation yields faster grasp adjustments than voluntary action, with a median response time of 0.30 (0.08) s, a rise time of 0.26 (0.03) s, an execution time of 0.56 (0.07) s, and a slip distance of 0.39 (0.10) cm. Prosthetic grip force is highly correlated to that of an intact hand, with a correlation coefficient of 96.85% (2.73%). These results demonstrate that it is feasible to reconstruct slip biomimetic sensorimotor pathways that provide grasp stability for prosthetic users.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2024-12-11
DOI
https://doi.org/10.3390/biomimetics9120751
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomimetic Strategies of Slip Sensing, Perception, and Protection in Prosthetic Hand Grasp

James L. Patton, Anran Xie, Jie Zhang, Zhuo‐Zhi Zhang et al.
1 citations
Biomimetics
Muscle activation and electromyography studies
0.18
article

Biomimetic Strategies of Slip Sensing, Perception, and Protection in Prosthetic Hand Grasp

James L. Patton, Anran Xie, Jie Zhang, Zhuo‐Zhi Zhang, Ning Lan, Weidong Chen, Tie Li
article en
1 citations

Abstract

This study develops biomimetic strategies for slip prevention in prosthetic hand grasps. The biomimetic system is driven by a novel slip sensor, followed by slip perception and preventive control. Here, we show that biologically inspired sensorimotor pathways can be restored between the prosthetic hand and users. A Ruffini endings-like slip sensor is used to detect shear forces and identify slip events directly. The slip information and grip force are encoded into a bi-state sensory coding that evokes vibration and buzz tactile sensations in subjects with transcutaneous electrical nerve stimulation (TENS). Subjects perceive slip events under various conditions based on the vibration sensation and voluntarily adjust grip force to prevent further slipping. Additionally, short-latency compensation for grip force is also implemented using a neuromorphic reflex pathway. The reflex loop includes a sensory neuron and interneurons to adjust the activations of antagonistic muscles reciprocally. The slip prevention system is tested in five able-bodied subjects and two transradial amputees with and without reflex compensation. A psychophysical test for perception reveals that the slip can be detected effectively, with a success accuracy of 96.57%. A slip protection test indicates that reflex compensation yields faster grasp adjustments than voluntary action, with a median response time of 0.30 (0.08) s, a rise time of 0.26 (0.03) s, an execution time of 0.56 (0.07) s, and a slip distance of 0.39 (0.10) cm. Prosthetic grip force is highly correlated to that of an intact hand, with a correlation coefficient of 96.85% (2.73%). These results demonstrate that it is feasible to reconstruct slip biomimetic sensorimotor pathways that provide grasp stability for prosthetic users.

BiomimeticsVol. 9(12)
Shanghai Jiao Tong University (CN), Chinese Academy of Sciences (CN), University of Illinois Chicago (US), Suzhou Institute of Nano-tech and Nano-bionics (CN)
National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality
Good health and well-being
Openalex Percentile: Top 50%
Muscle activation and electromyography studies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.