Understanding the role of S and Cl degrading the corrosion resistance of 12Cr1MoVG steel in a waste incineration boiler: on-site and laboratory testing

Abstract The corrosion behavior of 12Cr1MoVG tube in a waste incineration boiler superheater was investigated using on-site and laboratory testing. Low-melting-point ZnCl 2 and PbCl 2 induced the formation of eutectic mixtures. These eutectic mixtures captured ash particles, resulting in severe slagging on the 12Cr1MoVG tube. The structure of the oxide layer on the 12Cr1MoVG tube was severely disrupted by the high S and Cl contents in waste fuel. Under the influence of brittle Fe 2 O 3 and FeS spalling, FeCl 2 dissolution, FeCl 3 and FeSO 4 volatilization, and severe internal oxidation, corrosion perforation appeared in the 12Cr1MoVG tube.

Authors

Institutions

Publication Details

Journal
Corrosion Reviews
Published
2024-12-11
DOI
https://doi.org/10.1515/corrrev-2024-0079
Citations
1
Primary Topic
High-Temperature Coating Behaviors
Type
article
Field-Weighted Citation Impact
1.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the role of S and Cl degrading the corrosion resistance of 12Cr1MoVG steel in a waste incineration boiler: on-site and laboratory testing

Zhiyuan Liang, Haomin Wu, Shanshan Zhu, Tingshan Guo et al.
1 citations
Corrosion Reviews
High-Temperature Coating Behaviors
1.30
article

Understanding the role of S and Cl degrading the corrosion resistance of 12Cr1MoVG steel in a waste incineration boiler: on-site and laboratory testing

Zhiyuan Liang, Haomin Wu, Shanshan Zhu, Tingshan Guo, Qinxin Zhao
article en
1 citations

Abstract

Abstract The corrosion behavior of 12Cr1MoVG tube in a waste incineration boiler superheater was investigated using on-site and laboratory testing. Low-melting-point ZnCl 2 and PbCl 2 induced the formation of eutectic mixtures. These eutectic mixtures captured ash particles, resulting in severe slagging on the 12Cr1MoVG tube. The structure of the oxide layer on the 12Cr1MoVG tube was severely disrupted by the high S and Cl contents in waste fuel. Under the influence of brittle Fe 2 O 3 and FeS spalling, FeCl 2 dissolution, FeCl 3 and FeSO 4 volatilization, and severe internal oxidation, corrosion perforation appeared in the 12Cr1MoVG tube.

Corrosion ReviewsVol. 43(4)
Huangshan University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 11%
High-Temperature Coating Behaviors
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Understanding the role of S and Cl degrading the corrosion resistance of 12Cr1MoVG steel in a waste incineration boiler: on-site and laboratory testing — Zhiyuan Liang, Haomin Wu, et al. · Corrosion Reviews (2024) | TGRS Research Map | TGRS