A Rollar‐Type Resonant Photoacoustic Spectroscopy for Trace Gas Detection

ABSTRACT This paper presents a miniature Rollar‐type resonant photoacoustic cell (RRPAC), consisting of two cylindrical resonant cavities and a buffer chamber. The finite element analysis of the acoustic field distributions for the RRPAC and T‐type resonant photoacoustic cell (TRPAC) is utilized, demonstrating that RRPAC can produce a greater photoacoustic signal than the conventional TRPAC. A high sensitivity trace C 2 H 2 photoacoustic spectroscopy (PAS) system is successfully developed by combining a cantilever beam‐based acoustic sensor as the acoustic sensing unit and a high‐speed spectrometer as the demodulation unit with the RRPAC. The experimental results indicate that the 2f signal of the RRPAC at the first‐order resonance mode is approximately 1.5 times of the TRPAC with the same C 2 H 2 concentration. The gas detection limit of the RRPAC PAS system for C 2 H 2 is 40.7 ppb at an averaging time of 100 s. In comparison with the conventional TRPAC, the RRPAC exhibits higher sensitivity, thus providing a novel solution for the advancement of the PAS system.

Authors

Institutions

Publication Details

Journal
Microwave and Optical Technology Letters
Published
2024-12-01
DOI
https://doi.org/10.1002/mop.70060
Citations
4
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.96

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Rollar‐Type Resonant Photoacoustic Spectroscopy for Trace Gas Detection

Zhenfeng Gong, Liang Mei, Guojie Wu, Yongjia Zhang
4 citations
Microwave and Optical Technology Letters
Spectroscopy and Laser Applications
0.96
article

A Rollar‐Type Resonant Photoacoustic Spectroscopy for Trace Gas Detection

Zhenfeng Gong, Liang Mei, Guojie Wu, Yongjia Zhang
article en
4 citations

Abstract

ABSTRACT This paper presents a miniature Rollar‐type resonant photoacoustic cell (RRPAC), consisting of two cylindrical resonant cavities and a buffer chamber. The finite element analysis of the acoustic field distributions for the RRPAC and T‐type resonant photoacoustic cell (TRPAC) is utilized, demonstrating that RRPAC can produce a greater photoacoustic signal than the conventional TRPAC. A high sensitivity trace C 2 H 2 photoacoustic spectroscopy (PAS) system is successfully developed by combining a cantilever beam‐based acoustic sensor as the acoustic sensing unit and a high‐speed spectrometer as the demodulation unit with the RRPAC. The experimental results indicate that the 2f signal of the RRPAC at the first‐order resonance mode is approximately 1.5 times of the TRPAC with the same C 2 H 2 concentration. The gas detection limit of the RRPAC PAS system for C 2 H 2 is 40.7 ppb at an averaging time of 100 s. In comparison with the conventional TRPAC, the RRPAC exhibits higher sensitivity, thus providing a novel solution for the advancement of the PAS system.

Microwave and Optical Technology LettersVol. 66(12)
Dalian University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 26%
Spectroscopy and Laser Applications
0.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.