Design and analysis of G+5 residential building using E-tabs

High-rise buildings often contain basements, which are often assumed in structural analysis to be at a fixed ground level.However, basements introduce flexibility, leading to larger lateral displacements, longer vibration periods, and even changes in seismic response.For example, a 20-story building with a basement had a roof displacement of 13.8 cm compared to 12.7 cm without the basement, and its vibration period increased by 10%.Seismic loads also influence member forces in basements, and their consideration in structural analysis is necessary for accuracy.A matrix condensation procedure, which employs rigid diaphragms to reduce degrees of freedom in basement floors, has been proposed to address this issue effectively.In India, many G+15 reinforced concrete (RC) structures are constructed in high seismic zones without adherence to seismic coal provisions.This lack of compliance poses great risks to occupants, as earthquakes often expose the vulnerabilities of inadequately designed structures.The most common failure mechanism in such buildings is the soft story sway mechanism, where insufficient column strength causes large lateral displacements.

Authors

Publication Details

Journal
International Research Journal of Education and Technology (IRJET).
Published
2024-11-29
DOI
https://doi.org/10.70127/irjedt.vol.6.issue12.792
Primary Topic
BIM and Construction Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and analysis of G+5 residential building using E-tabs

A BHAGYALAXMI
International Research Journal of Education and Technology (IRJET).
BIM and Construction Integration
article

Design and analysis of G+5 residential building using E-tabs

A BHAGYALAXMI
article en

Abstract

High-rise buildings often contain basements, which are often assumed in structural analysis to be at a fixed ground level.However, basements introduce flexibility, leading to larger lateral displacements, longer vibration periods, and even changes in seismic response.For example, a 20-story building with a basement had a roof displacement of 13.8 cm compared to 12.7 cm without the basement, and its vibration period increased by 10%.Seismic loads also influence member forces in basements, and their consideration in structural analysis is necessary for accuracy.A matrix condensation procedure, which employs rigid diaphragms to reduce degrees of freedom in basement floors, has been proposed to address this issue effectively.In India, many G+15 reinforced concrete (RC) structures are constructed in high seismic zones without adherence to seismic coal provisions.This lack of compliance poses great risks to occupants, as earthquakes often expose the vulnerabilities of inadequately designed structures.The most common failure mechanism in such buildings is the soft story sway mechanism, where insufficient column strength causes large lateral displacements.

International Research Journal of Education and Technology (IRJET).Vol. 6(11)
Sustainable cities and communities
Openalex Percentile: Top 76%
BIM and Construction Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.