A Novel Magnetic Flux Leakage Method Incorporating TMR Sensors for Detecting Zinc Dross Defects on the Surface of Hot-Dip Galvanized Sheets

Surface quality control of hot-dip galvanized sheets is a critical research topic in the metallurgical industry. Zinc dross, the most common surface defect in the hot-dip galvanizing process, significantly affects the sheet’s service performance. In this manuscript, a novel magnetic flux leakage (MFL) detection method was proposed to detect zinc dross defects on the surface of hot-dip galvanized steel sheets. Instead of using exciting coils in traditional methods, a tiny permanent magnet with a millimeter magnitude was employed to reduce the size and weight of the equipment. Additionally, a high-precision tunnel magnetoresistance (TMR) sensor with a sensitivity of 300 mV/V/Oe was selected to achieve higher detection accuracy. The experimental setup was established, and the x-axis direction (sample movement direction) was determined as the best measurement axis by vector analysis through experiments and numerical simulation. The detection results indicate that this novel MFL detection method could detect industrial zinc dross with an equivalent size of 400 μm, with high signal repeatability and signal-to-noise ratio. In the range of 0–1200 mm/s, the detection speed has almost no effect on the measurement signal, which indicates that this novel method has higher adaptability to various conditions. The multi-path scanning method with a single probe was used to simulate the array measurement to detect a rectangular area of 30 × 60 mm. Ten zinc dross defects were detected across eight measurement paths with 4 mm intervals, and the positions of these zinc dross defects were successfully reconstructed. The research results indicate that this novel MFL detection method is simple and feasible. Furthermore, the implementation of array measurements provides valuable guidance for subsequent in-depth research and potential industrial applications in the future.

Authors

Institutions

Publication Details

Journal
Magnetochemistry
Published
2024-12-10
DOI
https://doi.org/10.3390/magnetochemistry10120101
Citations
2
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Magnetic Flux Leakage Method Incorporating TMR Sensors for Detecting Zinc Dross Defects on the Surface of Hot-Dip Galvanized Sheets

San Zhang, Jing Li, Bo Wang, Feilong Mao et al.
2 citations
Magnetochemistry
Non-Destructive Testing Techniques
0.43
article

A Novel Magnetic Flux Leakage Method Incorporating TMR Sensors for Detecting Zinc Dross Defects on the Surface of Hot-Dip Galvanized Sheets

San Zhang, Jing Li, Bo Wang, Feilong Mao, Jie Wang
article en
2 citations

Abstract

Surface quality control of hot-dip galvanized sheets is a critical research topic in the metallurgical industry. Zinc dross, the most common surface defect in the hot-dip galvanizing process, significantly affects the sheet’s service performance. In this manuscript, a novel magnetic flux leakage (MFL) detection method was proposed to detect zinc dross defects on the surface of hot-dip galvanized steel sheets. Instead of using exciting coils in traditional methods, a tiny permanent magnet with a millimeter magnitude was employed to reduce the size and weight of the equipment. Additionally, a high-precision tunnel magnetoresistance (TMR) sensor with a sensitivity of 300 mV/V/Oe was selected to achieve higher detection accuracy. The experimental setup was established, and the x-axis direction (sample movement direction) was determined as the best measurement axis by vector analysis through experiments and numerical simulation. The detection results indicate that this novel MFL detection method could detect industrial zinc dross with an equivalent size of 400 μm, with high signal repeatability and signal-to-noise ratio. In the range of 0–1200 mm/s, the detection speed has almost no effect on the measurement signal, which indicates that this novel method has higher adaptability to various conditions. The multi-path scanning method with a single probe was used to simulate the array measurement to detect a rectangular area of 30 × 60 mm. Ten zinc dross defects were detected across eight measurement paths with 4 mm intervals, and the positions of these zinc dross defects were successfully reconstructed. The research results indicate that this novel MFL detection method is simple and feasible. Furthermore, the implementation of array measurements provides valuable guidance for subsequent in-depth research and potential industrial applications in the future.

MagnetochemistryVol. 10(12)
Yuncheng University (CN), China Iron and Steel Research Institute Group (CN), Xi’an University of Posts and Telecommunications (CN)
Yuncheng University
Industry, innovation and infrastructure
Openalex Percentile: Top 40%
Non-Destructive Testing Techniques
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.