EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS

Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.

Authors

Institutions

Publication Details

Journal
Lékař a technika - Clinician and Technology
Published
2024-09-30
DOI
https://doi.org/10.14311/ctj.2024.3.01
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS

Kristyna Koldova, Tereza Blažková
Lékař a technika - Clinician and Technology
Electrical and Bioimpedance Tomography
article

EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS

Kristyna Koldova, Tereza Blažková
article en

Abstract

Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.

Lékař a technika - Clinician and TechnologyVol. 54(3)
Czech Technical University in Prague (CZ)
Openalex Percentile: Top 80%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EFFECT OF ELECTRODE BELT USED FOR LUNG MONITORING WITH ELECTRICAL IMPEDANCE TOMOGRAPHY ON TIDAL VOLUME IN HEALTHY SUBJECTS — Kristyna Koldova, Tereza Blažková · Lékař a technika - Clinician and Technology (2024) | TGRS Research Map | TGRS