Upscaling drag reduction of rotational rheometer to linear pipe flow

Drag reduction (DR) is a phenomenon associated with adding small amounts of drag-reducing agents to reduce friction causing a reduction in the pressure gradient needed for pumping a solution under turbulent conditions. Traditionally, DR has been measured with linear flow devices, such as flow loops. Recent developments in rheological measurement techniques have enabled the evaluation of DR using rotational rheometers. However, due to differences in flow nature and length scale, direct comparison between outcomes is not possible. This study introduces nondimensional quantities, namely dimensionless pressure difference for pipe flow and dimensionless torque for rheometers, as the basis for comparing the DR results of linear and rotational flow. Theoretically, the DR expressions derived from these dimensionless quantities showed similar structures, featuring a factor with quadratic viscosity and linear density terms. Experimentally, DR tests were carried out using an industrial-scale pipe flow and a laboratory-scale rotational rheometer, using solutions of tap water with high-viscosity partially hydrolyzed polyacrylamide at two molecular weights. Samples tested with the rheometer were collected from flow loop experiments, ensuring the same polymer solutions were tested with both devices. Results showed that DR, expressed as a function of Reynolds number using nondimensional measurements, follows similar behavior for both instruments. The experimental DR results from the rheometer were extrapolated to the pipe flow scale, showing overall agreement between extrapolated and experimental results. These findings suggest that rotational rheometers could effectively replace linear flow instruments for screening polymer solutions in DR applications.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-12-01
DOI
https://doi.org/10.1063/5.0241608
Citations
3
Primary Topic
Rheology and Fluid Dynamics Studies
Type
article
Field-Weighted Citation Impact
0.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Upscaling drag reduction of rotational rheometer to linear pipe flow

Kotaybah Hashlamoun, Nashaat N. Nassar, Saleh S. Baakeem, A. Zabi
3 citations
Physics of Fluids
Rheology and Fluid Dynamics Studies
0.65
article

Upscaling drag reduction of rotational rheometer to linear pipe flow

Kotaybah Hashlamoun, Nashaat N. Nassar, Saleh S. Baakeem, A. Zabi
article en
3 citations

Abstract

Drag reduction (DR) is a phenomenon associated with adding small amounts of drag-reducing agents to reduce friction causing a reduction in the pressure gradient needed for pumping a solution under turbulent conditions. Traditionally, DR has been measured with linear flow devices, such as flow loops. Recent developments in rheological measurement techniques have enabled the evaluation of DR using rotational rheometers. However, due to differences in flow nature and length scale, direct comparison between outcomes is not possible. This study introduces nondimensional quantities, namely dimensionless pressure difference for pipe flow and dimensionless torque for rheometers, as the basis for comparing the DR results of linear and rotational flow. Theoretically, the DR expressions derived from these dimensionless quantities showed similar structures, featuring a factor with quadratic viscosity and linear density terms. Experimentally, DR tests were carried out using an industrial-scale pipe flow and a laboratory-scale rotational rheometer, using solutions of tap water with high-viscosity partially hydrolyzed polyacrylamide at two molecular weights. Samples tested with the rheometer were collected from flow loop experiments, ensuring the same polymer solutions were tested with both devices. Results showed that DR, expressed as a function of Reynolds number using nondimensional measurements, follows similar behavior for both instruments. The experimental DR results from the rheometer were extrapolated to the pipe flow scale, showing overall agreement between extrapolated and experimental results. These findings suggest that rotational rheometers could effectively replace linear flow instruments for screening polymer solutions in DR applications.

Physics of FluidsVol. 36(12)
University of Calgary (CA)
RES’EAU-WaterNET
Clean water and sanitation
Openalex Percentile: Top 36%
Rheology and Fluid Dynamics Studies
0.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.