Marine variable air volume air conditioning system modeling and simulation

Abstract Air conditioning system is one of the significant energy consumption systems in Marine ship operations, and its economic operation is a vital measurement index. Variable Air Volume (VAV) air-conditioning system have gradually become mainstream air conditioning system on account of its remarkable energy saving. This study presents the fundamental concept and features, and active disturbance rejection control (ADRC) serves as the foundation for the proposed approach. A simulation study in MATLAB/Simulink has made a comparison with the PID controller, and the conclusion provides a reference value for the design and application of the VAV conditioning system.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-11-01
DOI
https://doi.org/10.1088/1742-6596/2902/1/012037
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Marine variable air volume air conditioning system modeling and simulation

Jie Lü, Zhen Fang, Minghao Chen, Fan Zhuo et al.
1 citations
Journal of Physics Conference Series
Refrigeration and Air Conditioning Technologies
0.21
article

Marine variable air volume air conditioning system modeling and simulation

Jie Lü, Zhen Fang, Minghao Chen, Fan Zhuo, Xiaojun Yi, Jing Huang, Qian Liu
article en
1 citations

Abstract

Abstract Air conditioning system is one of the significant energy consumption systems in Marine ship operations, and its economic operation is a vital measurement index. Variable Air Volume (VAV) air-conditioning system have gradually become mainstream air conditioning system on account of its remarkable energy saving. This study presents the fundamental concept and features, and active disturbance rejection control (ADRC) serves as the foundation for the proposed approach. A simulation study in MATLAB/Simulink has made a comparison with the PID controller, and the conclusion provides a reference value for the design and application of the VAV conditioning system.

Journal of Physics Conference SeriesVol. 2902(1)
Wuhan Ship Development & Design Institute (CN)
Openalex Percentile: Top 49%
Refrigeration and Air Conditioning Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.