Techno-Economic Analysis of Roof Insulation Strategies for Decarbonizing Commercial and Residential Buildings in Malaysia

Building energy consumption in Malaysia has increased by 31% over the past 10 years, primarily driven by the high demand for air conditioning in response to the country’s hot and humid climate. An effective way to address this problem is to increase building energy efficiency with the aid of thermal insulation. This paper presents a techno-economic analysis of roof assembly retrofits for commercial and residential buildings in Malaysia. Various roof configurations incorporating insulation materials such as radiant barriers, reflective insulation, mineral glass wool, and stone wool are investigated. The first section of this paper details the use of Sefaira building energy simulation software to evaluate the annual reduction in cooling energy consumption achieved by various roof configurations for commercial and residential buildings. Subsequently, an economic analysis is conducted by calculating the internal rate of return (IRR) and payback period for investment in each type of roof configuration. The findings show that roof assembly retrofits can reduce annual cooling energy consumption in commercial buildings by 8.65% to 16.25% and in residential buildings by 11.1% to 13.8%. Additionally, the total annual energy consumption decreases by 4.70% to 8.83% for commercial buildings, such as hypermarkets, and by 4.10% to 6.10% for residential buildings, depending on the insulation system applied. The economic analysis shows that the roof assembly insulated with a radiant barrier and thick enclosed air gap is the most economically beneficial option, offering the highest IRR of 20.60% and 6.79% for commercial and residential buildings, respectively, and the shortest payback periods of 4.6 years and 11.2 years, respectively. These results provide valuable insights to guide building owners and designers in choosing the most cost-effective type of roof insulation for new or existing projects.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-12-10
DOI
https://doi.org/10.3390/buildings14123933
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techno-Economic Analysis of Roof Insulation Strategies for Decarbonizing Commercial and Residential Buildings in Malaysia

Nur Haziqah Mohamad Zaidi, Lim Chin Haw, Muhamad Zahin Mohd Ashhar
Buildings
Building Energy and Comfort Optimization
article

Techno-Economic Analysis of Roof Insulation Strategies for Decarbonizing Commercial and Residential Buildings in Malaysia

Nur Haziqah Mohamad Zaidi, Lim Chin Haw, Muhamad Zahin Mohd Ashhar
article en

Abstract

Building energy consumption in Malaysia has increased by 31% over the past 10 years, primarily driven by the high demand for air conditioning in response to the country’s hot and humid climate. An effective way to address this problem is to increase building energy efficiency with the aid of thermal insulation. This paper presents a techno-economic analysis of roof assembly retrofits for commercial and residential buildings in Malaysia. Various roof configurations incorporating insulation materials such as radiant barriers, reflective insulation, mineral glass wool, and stone wool are investigated. The first section of this paper details the use of Sefaira building energy simulation software to evaluate the annual reduction in cooling energy consumption achieved by various roof configurations for commercial and residential buildings. Subsequently, an economic analysis is conducted by calculating the internal rate of return (IRR) and payback period for investment in each type of roof configuration. The findings show that roof assembly retrofits can reduce annual cooling energy consumption in commercial buildings by 8.65% to 16.25% and in residential buildings by 11.1% to 13.8%. Additionally, the total annual energy consumption decreases by 4.70% to 8.83% for commercial buildings, such as hypermarkets, and by 4.10% to 6.10% for residential buildings, depending on the insulation system applied. The economic analysis shows that the roof assembly insulated with a radiant barrier and thick enclosed air gap is the most economically beneficial option, offering the highest IRR of 20.60% and 6.79% for commercial and residential buildings, respectively, and the shortest payback periods of 4.6 years and 11.2 years, respectively. These results provide valuable insights to guide building owners and designers in choosing the most cost-effective type of roof insulation for new or existing projects.

BuildingsVol. 14(12)
National Institutes of Biotechnology Malaysia (MY), National University of Malaysia (MY)
Affordable and clean energy
Openalex Percentile: Top 76%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.