Enhancing nondestructive mass identification via Fourier-transform fluorescence analysis

Single-ion mass identification is important for atomic and nuclear physics experiments on ions produced with low yields. Cooling the ion to ultralow temperatures through interaction with a laser-cooled ion will enhance the precision of the measurements. In this paper we present axial-common-mode frequency measurements of balanced and unbalanced Coulomb crystals from the Fourier transform of the fluorescence photons from a Doppler-cooling transition in calcium ions after probing the ion crystal with a five-radio-frequency comb. A single ion nondestructively detected can be used for identification, yielding a mass-resolving power <a:math xmlns:a="http://www.w3.org/1998/Math/MathML"><a:mrow><a:mi>m</a:mi><a:mo>/</a:mo><a:mi mathvariant="normal">Δ</a:mi><a:msub><a:mi>m</a:mi><a:mi>FWHM</a:mi></a:msub><a:mo>≈</a:mo><a:mn>310</a:mn></a:mrow></a:math> from the axial common mode. This identification can be performed from a single measurement within times below 1 s. Published by the American Physical Society 2024

Authors

Institutions

Publication Details

Journal
Physical Review Research
Published
2024-12-10
DOI
https://doi.org/10.1103/physrevresearch.6.043255
Primary Topic
Advanced Fiber Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing nondestructive mass identification via Fourier-transform fluorescence analysis

M. Block, M. J. Gutiérrez, J. Berrocal, Francisco Domínguez et al.
Physical Review Research
Advanced Fiber Laser Technologies
article

Enhancing nondestructive mass identification via Fourier-transform fluorescence analysis

M. Block, M. J. Gutiérrez, J. Berrocal, Francisco Domínguez, D. Rodrı́guez, Juan M. Sánchez, David Yousaf
article en

Abstract

Single-ion mass identification is important for atomic and nuclear physics experiments on ions produced with low yields. Cooling the ion to ultralow temperatures through interaction with a laser-cooled ion will enhance the precision of the measurements. In this paper we present axial-common-mode frequency measurements of balanced and unbalanced Coulomb crystals from the Fourier transform of the fluorescence photons from a Doppler-cooling transition in calcium ions after probing the ion crystal with a five-radio-frequency comb. A single ion nondestructively detected can be used for identification, yielding a mass-resolving power <a:math xmlns:a="http://www.w3.org/1998/Math/MathML"><a:mrow><a:mi>m</a:mi><a:mo>/</a:mo><a:mi mathvariant="normal">Δ</a:mi><a:msub><a:mi>m</a:mi><a:mi>FWHM</a:mi></a:msub><a:mo>≈</a:mo><a:mn>310</a:mn></a:mrow></a:math> from the axial common mode. This identification can be performed from a single measurement within times below 1 s. Published by the American Physical Society 2024

Physical Review ResearchVol. 6(4)
GSI Helmholtz Centre for Heavy Ion Research (DE), Universidad de Granada (ES), Johannes Gutenberg University Mainz (DE), Helmholtz Institute Mainz (DE)
Ministerio de Ciencia e Innovación, Universidad de Granada, European Research Council, European Regional Development Fund
Openalex Percentile: Top 79%
Advanced Fiber Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.