Analyzing the Impact of Binaural Beats on Anxiety Levels by a New Method Based on Denoised Harmonic Subtraction and Transient Temporal Feature Extraction

Anxiety is a widespread mental health issue, and binaural beats have been explored as a potential non-invasive treatment. EEG data reveal changes in neural oscillation and connectivity linked to anxiety reduction; however, harmonics introduced during signal acquisition and processing often distort these findings. Existing methods struggle to effectively reduce harmonics and capture the fine-grained temporal dynamics of EEG signals, leading to inaccurate feature extraction. Hence, a novel Denoised Harmonic Subtraction and Transient Temporal Feature Extraction is proposed to improve the analysis of the impact of binaural beats on anxiety levels. Initially, a novel Wiener Fused Convo Filter is introduced to capture spatial features and eliminate linear noise in EEG signals. Next, an Intrinsic Harmonic Subtraction Network is employed, utilizing the Attentive Weighted Least Mean Square (AW-LMS) algorithm to capture nonlinear summation and resonant coupling effects, effectively eliminating the misinterpretation of brain rhythms. To address the challenge of fine-grained temporal dynamics, an Embedded Transfo XL Recurrent Network is introduced to detect and extract relevant parameters associated with transient events in EEG data. Finally, EEG data undergo harmonic reduction and temporal feature extraction before classification with a cross-correlated Markov Deep Q-Network (DQN). This facilitates anxiety level classification into normal, mild, moderate, and severe categories. The model demonstrated a high accuracy of 95.6%, precision of 90%, sensitivity of 93.2%, and specificity of 96% in classifying anxiety levels, outperforming previous models. This integrated approach enhances EEG signal processing, enabling reliable anxiety classification and offering valuable insights for therapeutic interventions.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-12-10
DOI
https://doi.org/10.3390/bioengineering11121251
Citations
1
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analyzing the Impact of Binaural Beats on Anxiety Levels by a New Method Based on Denoised Harmonic Subtraction and Transient Temporal Feature Extraction

Avireni Srinivasulu, Nicu Bizon, Bharati Ainapure, Devika Rankhambe et al.
1 citations
Bioengineering
EEG and Brain-Computer Interfaces
0.34
article

Analyzing the Impact of Binaural Beats on Anxiety Levels by a New Method Based on Denoised Harmonic Subtraction and Transient Temporal Feature Extraction

Avireni Srinivasulu, Nicu Bizon, Bharati Ainapure, Devika Rankhambe, Bhargav Appasani
article en
1 citations

Abstract

Anxiety is a widespread mental health issue, and binaural beats have been explored as a potential non-invasive treatment. EEG data reveal changes in neural oscillation and connectivity linked to anxiety reduction; however, harmonics introduced during signal acquisition and processing often distort these findings. Existing methods struggle to effectively reduce harmonics and capture the fine-grained temporal dynamics of EEG signals, leading to inaccurate feature extraction. Hence, a novel Denoised Harmonic Subtraction and Transient Temporal Feature Extraction is proposed to improve the analysis of the impact of binaural beats on anxiety levels. Initially, a novel Wiener Fused Convo Filter is introduced to capture spatial features and eliminate linear noise in EEG signals. Next, an Intrinsic Harmonic Subtraction Network is employed, utilizing the Attentive Weighted Least Mean Square (AW-LMS) algorithm to capture nonlinear summation and resonant coupling effects, effectively eliminating the misinterpretation of brain rhythms. To address the challenge of fine-grained temporal dynamics, an Embedded Transfo XL Recurrent Network is introduced to detect and extract relevant parameters associated with transient events in EEG data. Finally, EEG data undergo harmonic reduction and temporal feature extraction before classification with a cross-correlated Markov Deep Q-Network (DQN). This facilitates anxiety level classification into normal, mild, moderate, and severe categories. The model demonstrated a high accuracy of 95.6%, precision of 90%, sensitivity of 93.2%, and specificity of 96% in classifying anxiety levels, outperforming previous models. This integrated approach enhances EEG signal processing, enabling reliable anxiety classification and offering valuable insights for therapeutic interventions.

BioengineeringVol. 11(12)
Vishwakarma University, KIIT University (IN)
Openalex Percentile: Top 38%
EEG and Brain-Computer Interfaces
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.