Refractive Outcome, Lens Power Calculation, and Surgically Induced Astigmatism After Four-Flanged Intrascleral Intraocular Lens Fixation

This study demonstrates that the four-flanged technique for scleral IOL fixation yields reliable outcomes. PE was closest to zero using the Hoffer-Q formula, although there was no statistically significant difference compared to the other formulas. Axial length emerged as the most pertinent factor for PE. Short eyes resulted in a more hyperopic outcome, whereas longer eyes resulted in a more myopic outcome than intended. This myopic and hyperopic shift was due to the standardized surgical technique with an externalization of the haptics 2.5 mm behind the limbus resulting in a consistent aqueous anterior chamber depth across all eye lengths, coupled with a reduction or increase in the distance from the IOL to the macula, which is dependent on the length of the eye. <b>[<i>J Refract Surg</i>. 2024;40(12):e985-e993.]</b>.

Authors

Institutions

Publication Details

Journal
Journal of Refractive Surgery
Published
2024-12-01
DOI
https://doi.org/10.3928/1081597x-20241021-01
Citations
2
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
1.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Refractive Outcome, Lens Power Calculation, and Surgically Induced Astigmatism After Four-Flanged Intrascleral Intraocular Lens Fixation

Daniel Schartmüller, Victor Danzinger, Ioanna Dimakopoulou, Markus Schranz et al.
2 citations
Journal of Refractive Surgery
Intraocular Surgery and Lenses
1.08
article

Refractive Outcome, Lens Power Calculation, and Surgically Induced Astigmatism After Four-Flanged Intrascleral Intraocular Lens Fixation

Daniel Schartmüller, Victor Danzinger, Ioanna Dimakopoulou, Markus Schranz, Marcus Lisy, Claudette Abela‐Formanek
article en
2 citations

Abstract

This study demonstrates that the four-flanged technique for scleral IOL fixation yields reliable outcomes. PE was closest to zero using the Hoffer-Q formula, although there was no statistically significant difference compared to the other formulas. Axial length emerged as the most pertinent factor for PE. Short eyes resulted in a more hyperopic outcome, whereas longer eyes resulted in a more myopic outcome than intended. This myopic and hyperopic shift was due to the standardized surgical technique with an externalization of the haptics 2.5 mm behind the limbus resulting in a consistent aqueous anterior chamber depth across all eye lengths, coupled with a reduction or increase in the distance from the IOL to the macula, which is dependent on the length of the eye. <b>[<i>J Refract Surg</i>. 2024;40(12):e985-e993.]</b>.

Journal of Refractive SurgeryVol. 40(12)
Medical University of Vienna (AT)
Good health and well-being
Openalex Percentile: Top 21%
Intraocular Surgery and Lenses
1.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.