Mitigating high frame rate demands in shear wave elastography using radial basis function-based reconstruction: An experimental phantom study

The results obtained from employing the proposed model on two experimental datasets indicate that we can relax the frame rate requirement of SWE imaging by a factor of 4 while maintaining shear wave speed (SWS), group velocity, and phase velocity estimates closely align with the high frame rate SWE model so that the error is less than 3%. Furthermore, analysis of the structural similarity index (SSIM) and root mean squared error (RMSE) on the 2D-SWS maps highlights the efficacy of the suggested technique in enhancing local SWS estimates, even at a downsampling (DS) factor of 4. For DS≤4, the SSIM values between the 2D-SWS maps produced by the proposed technique and those generated by the original high frame rate data consistently remain above 0.94. Additionally, the RMSE values is below 0.37 m/s, indicating promising performance of the proposed technique in reconstruction of SWS values.

Authors

Institutions

Publication Details

Journal
Ultrasonics
Published
2024-12-10
DOI
https://doi.org/10.1016/j.ultras.2024.107542
Citations
1
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating high frame rate demands in shear wave elastography using radial basis function-based reconstruction: An experimental phantom study

Libertario Demi, Sajjad Afrakhteh
1 citations
Ultrasonics
Ultrasonics and Acoustic Wave Propagation
0.27
article

Mitigating high frame rate demands in shear wave elastography using radial basis function-based reconstruction: An experimental phantom study

Libertario Demi, Sajjad Afrakhteh
article en
1 citations

Abstract

The results obtained from employing the proposed model on two experimental datasets indicate that we can relax the frame rate requirement of SWE imaging by a factor of 4 while maintaining shear wave speed (SWS), group velocity, and phase velocity estimates closely align with the high frame rate SWE model so that the error is less than 3%. Furthermore, analysis of the structural similarity index (SSIM) and root mean squared error (RMSE) on the 2D-SWS maps highlights the efficacy of the suggested technique in enhancing local SWS estimates, even at a downsampling (DS) factor of 4. For DS≤4, the SSIM values between the 2D-SWS maps produced by the proposed technique and those generated by the original high frame rate data consistently remain above 0.94. Additionally, the RMSE values is below 0.37 m/s, indicating promising performance of the proposed technique in reconstruction of SWS values.

UltrasonicsVol. 148
University of Trento (IT)
Climate action
Openalex Percentile: Top 47%
Ultrasonics and Acoustic Wave Propagation
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.