Simplified optical monitoring systems for detecting leukocyte-derived hypochlorite ions using small amounts of whole blood

Here, we developed two simplified optical systems, FLP-H3200 and FLP-H4200, designed to detect leukocyte-derived hypochlorite ions via fluorescence (FL-OCl − ) using only three microliters of whole blood. First, the new systems employed a lower-cost photodiode as the photodetector instead of a photomultiplier tube in their preceding system CFL-H2200. The systems featured a simplified optical configuration optimized for the blood measurement fluidic chip, enabling efficient focusing of the desired FL-OCl − signal and obtaining a signal intensity comparable to that obtained with CFL-H2200. These improvements made the new systems more compact, lightweight, and cost-effective than CFL-H2200. Additionally, in FLP-H4200, the intensity of the excitation light source, the light-emitting diode, was set higher than that in FLP-H3200, further enhancing the FL-OCl − signal. Using the fluorescent reagent fluorescein, we confirmed that the fluorescence sensitivity of the new systems was comparable to that of CFL-H2200. Finally, blood analysis data using FLP-H3200 and FLP-H4200 showed a high correlation. This study broadens the scope of clinical examinations by providing accessible and efficient tools for monitoring leukocyte activity using whole blood. • FLP-H3200 and FLP-H4200 were developed to monitor OCl − ions produced by leukocytes. • These systems are more compact, lightweight, and cost-effective than previous ones. • The fluidic chip used enables detection using three microliters of whole blood. • FLP-H4200 delivers increased fluorescence signals with a higher LED intensity. • Signals from FLP-H3200 and FLP-H4200 show a strong positive correlation.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2024-12-10
DOI
https://doi.org/10.1016/j.sbsr.2024.100722
Citations
4
Primary Topic
Neutrophil, Myeloperoxidase and Oxidative Mechanisms
Type
article
Field-Weighted Citation Impact
0.96

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplified optical monitoring systems for detecting leukocyte-derived hypochlorite ions using small amounts of whole blood

K. Takeuchi, Kimiko Kazumura, Hiroshi Tsuchiya, Takayuki Sato et al.
4 citations
Sensing and Bio-Sensing Research
Neutrophil, Myeloperoxidase and Oxidative Mechanisms
0.96
article

Simplified optical monitoring systems for detecting leukocyte-derived hypochlorite ions using small amounts of whole blood

K. Takeuchi, Kimiko Kazumura, Hiroshi Tsuchiya, Takayuki Sato, Toshiyuki Miwa, Takahiro Shikayama
article en
4 citations

Abstract

Here, we developed two simplified optical systems, FLP-H3200 and FLP-H4200, designed to detect leukocyte-derived hypochlorite ions via fluorescence (FL-OCl − ) using only three microliters of whole blood. First, the new systems employed a lower-cost photodiode as the photodetector instead of a photomultiplier tube in their preceding system CFL-H2200. The systems featured a simplified optical configuration optimized for the blood measurement fluidic chip, enabling efficient focusing of the desired FL-OCl − signal and obtaining a signal intensity comparable to that obtained with CFL-H2200. These improvements made the new systems more compact, lightweight, and cost-effective than CFL-H2200. Additionally, in FLP-H4200, the intensity of the excitation light source, the light-emitting diode, was set higher than that in FLP-H3200, further enhancing the FL-OCl − signal. Using the fluorescent reagent fluorescein, we confirmed that the fluorescence sensitivity of the new systems was comparable to that of CFL-H2200. Finally, blood analysis data using FLP-H3200 and FLP-H4200 showed a high correlation. This study broadens the scope of clinical examinations by providing accessible and efficient tools for monitoring leukocyte activity using whole blood. • FLP-H3200 and FLP-H4200 were developed to monitor OCl − ions produced by leukocytes. • These systems are more compact, lightweight, and cost-effective than previous ones. • The fluidic chip used enables detection using three microliters of whole blood. • FLP-H4200 delivers increased fluorescence signals with a higher LED intensity. • Signals from FLP-H3200 and FLP-H4200 show a strong positive correlation.

Sensing and Bio-Sensing ResearchVol. 47
Hamamatsu Photonics (Japan) (JP)
National Agriculture and Food Research Organization, Council for Science, Technology and Innovation, Bio-oriented Technology Research Advancement Institution
Openalex Percentile: Top 24%
Neutrophil, Myeloperoxidase and Oxidative Mechanisms
0.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.