SEM contour extraction application on OPC model of contact layer

There are many kinds of OPC test pattern in Contact (CT) layer, and different measurement methods are used to measure the model data, resulting in a large simulation error of y-direction rectangle type patterns in the model. We propose a new method to build OPC model of CT layer by using SEM image contour. In this work, the SEM image contour was extracted by Calibre SEMSuite™, and the measurements of the corresponding test pattern was calculated according to the image contour. The CD-SEM (critical dimension scanning electron microscope) measurement data of anchor point was used to calibrate the modeling data and then the OPC model was built. Compared with the model tuned by CD measurements, the simulation error of y-direction rectangle type patterns caused by measurement method is effectively reduced. Our experiments show that it is feasible to build a high precision OPC model of CT layer by using this method.

Authors

Institutions

Publication Details

Published
2024-12-10
DOI
https://doi.org/10.1117/12.3052691
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SEM contour extraction application on OPC model of contact layer

Xiangshang Zhu, Shibin Xu, Ming Yao, Dawei Gao et al.
Electron and X-Ray Spectroscopy Techniques
article

SEM contour extraction application on OPC model of contact layer

Xiangshang Zhu, Shibin Xu, Ming Yao, Dawei Gao, Yongyu Wu, Zhi‐Ping Yan, Ken Chen, Feng Shao, Chenwei Sun, Kun Ren, Xinyuan Zhang
article en

Abstract

There are many kinds of OPC test pattern in Contact (CT) layer, and different measurement methods are used to measure the model data, resulting in a large simulation error of y-direction rectangle type patterns in the model. We propose a new method to build OPC model of CT layer by using SEM image contour. In this work, the SEM image contour was extracted by Calibre SEMSuite™, and the measurements of the corresponding test pattern was calculated according to the image contour. The CD-SEM (critical dimension scanning electron microscope) measurement data of anchor point was used to calibrate the modeling data and then the OPC model was built. Compared with the model tuned by CD measurements, the simulation error of y-direction rectangle type patterns caused by measurement method is effectively reduced. Our experiments show that it is feasible to build a high precision OPC model of CT layer by using this method.

Siemens (China) (CN)
Openalex Percentile: Top 79%
Electron and X-Ray Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.