Optimal cascade 2DOF fractional order master-slave controller design for LFC of hybrid microgrid systems with EV charging technology

This paper addresses the increasing complexity and evolving challenges in recent power systems management, particularly under the integration of diverse renewable energy sources (RESs) and advanced control technologies. With the rising unpredictability of power generation due to RESs and the diminishing system inertia, robust load frequency control (LFC) solutions are desperately needed to maintain network stability and manage frequency variations. This work proposes improved FOCs for achieving load frequency control (LFC) and the virtual inertia control (VIC) provision of electric vehicles (EVs) batteries. The proposed method includes a twofold contribution using a new fractional-order LFC method.The proposed technique is innovative by merging the characteristics of cascaded 2-degree of freedom (2DOF) configuration, incorporating both tilt-integral-derivative-filter (FOTIDN) and tilt-derivative-filter (FOTDN) controllers. This method is designed to enhance the robustness of interconnected multi-microgrid systems against disturbances from RESs and load demand fluctuations. Moreover, this paper presents the application of the Marine Predators Algorithm (MPA) for optimizing the proposed controller's parameters across various interconnected systems. Through simulation and time-domain analysis, the efficacy of the proposed technique is assessed in a range of load scenarios and uncertainty levels, exhibiting superior performance in contrast to current LFC methodologies such as TID, FOTID, TID-FOPIDN, and 2DOF TIDN-TDN. The results indicate that the advanced 2DOF FOTIDN-FOTDN controller based on the MPA significantly improves system response and stability, marking a pivotal advancement in power system control strategies. Moreover, the employing of MPA optimizer is compared with the widely-used optimizers in the literature, including the MRFO, ABC, and PSO optimizers at the different objective functions of IAE, ISE, ITAE, and ITSE. For instance, the MPA method has a minimized ITAE after 30 iterations of 0.027 compared to 0.0276 with MRFO, 0.0282 with ABC, and 0.034 with PSO optimizer. Thence, fast and better minimization of objective functions are achieved using the proposed MPA. • An innovative method for optimizing fractional-order LFC is developed. • A novel cascaded 2DOF including FO tilt-integral-derivative-filter (FOTIDN) and fractional order tilt-derivative-filter (FOTDN), termed as 2DOF FOTIDN-FOTDN. • The proposed controller cooperating with EVs for regulating the system output due to variations in load demand and uncertainty in renewable energy sources (RESs). • An in-depth comparison with other literature control schemes executed to validate the new cascaded controller.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-12-10
DOI
https://doi.org/10.1016/j.rineng.2024.103647
Citations
9
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal cascade 2DOF fractional order master-slave controller design for LFC of hybrid microgrid systems with EV charging technology

Mohamed M. Aly, Ahmed Elmelegi, Ali Selim, Emad A. Mohamed et al.
9 citations
Results in Engineering
Frequency Control in Power Systems
1.88
article

Optimal cascade 2DOF fractional order master-slave controller design for LFC of hybrid microgrid systems with EV charging technology

Mohamed M. Aly, Ahmed Elmelegi, Ali Selim, Emad A. Mohamed, Amira A. Hassan, A.O. Aldhaibani
article en
9 citations

Abstract

This paper addresses the increasing complexity and evolving challenges in recent power systems management, particularly under the integration of diverse renewable energy sources (RESs) and advanced control technologies. With the rising unpredictability of power generation due to RESs and the diminishing system inertia, robust load frequency control (LFC) solutions are desperately needed to maintain network stability and manage frequency variations. This work proposes improved FOCs for achieving load frequency control (LFC) and the virtual inertia control (VIC) provision of electric vehicles (EVs) batteries. The proposed method includes a twofold contribution using a new fractional-order LFC method.The proposed technique is innovative by merging the characteristics of cascaded 2-degree of freedom (2DOF) configuration, incorporating both tilt-integral-derivative-filter (FOTIDN) and tilt-derivative-filter (FOTDN) controllers. This method is designed to enhance the robustness of interconnected multi-microgrid systems against disturbances from RESs and load demand fluctuations. Moreover, this paper presents the application of the Marine Predators Algorithm (MPA) for optimizing the proposed controller's parameters across various interconnected systems. Through simulation and time-domain analysis, the efficacy of the proposed technique is assessed in a range of load scenarios and uncertainty levels, exhibiting superior performance in contrast to current LFC methodologies such as TID, FOTID, TID-FOPIDN, and 2DOF TIDN-TDN. The results indicate that the advanced 2DOF FOTIDN-FOTDN controller based on the MPA significantly improves system response and stability, marking a pivotal advancement in power system control strategies. Moreover, the employing of MPA optimizer is compared with the widely-used optimizers in the literature, including the MRFO, ABC, and PSO optimizers at the different objective functions of IAE, ISE, ITAE, and ITSE. For instance, the MPA method has a minimized ITAE after 30 iterations of 0.027 compared to 0.0276 with MRFO, 0.0282 with ABC, and 0.034 with PSO optimizer. Thence, fast and better minimization of objective functions are achieved using the proposed MPA. • An innovative method for optimizing fractional-order LFC is developed. • A novel cascaded 2DOF including FO tilt-integral-derivative-filter (FOTIDN) and fractional order tilt-derivative-filter (FOTDN), termed as 2DOF FOTIDN-FOTDN. • The proposed controller cooperating with EVs for regulating the system output due to variations in load demand and uncertainty in renewable energy sources (RESs). • An in-depth comparison with other literature control schemes executed to validate the new cascaded controller.

Results in EngineeringVol. 25
Prince Sattam Bin Abdulaziz University (SA), Hadhramout University (YE), Aswan University (EG)
Prince Sattam bin Abdulaziz University
Openalex Percentile: Top 14%
Frequency Control in Power Systems
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.