Highly Sensitivity Streptomycin Sulfate Sensor Based on Microfiber Coupler With Vernier Effect

Streptomycin sulfate (STS) is one of the major sources of contamination in water. Excessive intake of STS can be a serious health hazard to humans, causing vestibular and auditory nerve damage, nephrotoxicity, myasthenia gravis, or Parkinson’s disease. To address this, we propose an STS concentration sensor leveraging multiwalled carbon nanotubes (MWCNTs) and the Vernier effect of a microfiber coupler (MFC). The Vernier effect of MFC is caused by the interference of two supermodes in two orthogonal polarizations in a refringent optical fiber, and the high sensitivity can be achieved directly by monitoring the Vernier envelope. MWCNTs can adsorb more biomolecules to enhance the light absorption of analytes to further improve the detection sensitivity. The influence of MFC structure parameters on sensor performance is analyzed by simulation and verified by experiment. Theoretical analyses and experimental results indicate that for specific diameter MFC, the sensor will have better performance. The sensor exhibits a remarkably high sensitivity of 1577.5 nm/(mg/ml) in the detection range of 0.02–0.1 mg/ml, namely sensitivity amplification factor nearly one order of magnitude, and the sensor achieves an ultralow limit of detection (LOD) of 12.68 ng/ml. The Vernier effect of MFC and the modification of MWCNTs effectively enhance the sensitivity of the STS sensor. The device does not require complex pretreatment or antibody preparation, making it highly promising for applications in food safety, environmental pollution, and health monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-12-11
DOI
https://doi.org/10.1109/jsen.2024.3510773
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitivity Streptomycin Sulfate Sensor Based on Microfiber Coupler With Vernier Effect

Yanxi Wang, Yinping Miao, Mingpan Bi, Xiaolan Li et al.
IEEE Sensors Journal
Analytical Chemistry and Sensors
article

Highly Sensitivity Streptomycin Sulfate Sensor Based on Microfiber Coupler With Vernier Effect

Yanxi Wang, Yinping Miao, Mingpan Bi, Xiaolan Li, Jie Liu, Yang Zhang
article en

Abstract

Streptomycin sulfate (STS) is one of the major sources of contamination in water. Excessive intake of STS can be a serious health hazard to humans, causing vestibular and auditory nerve damage, nephrotoxicity, myasthenia gravis, or Parkinson’s disease. To address this, we propose an STS concentration sensor leveraging multiwalled carbon nanotubes (MWCNTs) and the Vernier effect of a microfiber coupler (MFC). The Vernier effect of MFC is caused by the interference of two supermodes in two orthogonal polarizations in a refringent optical fiber, and the high sensitivity can be achieved directly by monitoring the Vernier envelope. MWCNTs can adsorb more biomolecules to enhance the light absorption of analytes to further improve the detection sensitivity. The influence of MFC structure parameters on sensor performance is analyzed by simulation and verified by experiment. Theoretical analyses and experimental results indicate that for specific diameter MFC, the sensor will have better performance. The sensor exhibits a remarkably high sensitivity of 1577.5 nm/(mg/ml) in the detection range of 0.02–0.1 mg/ml, namely sensitivity amplification factor nearly one order of magnitude, and the sensor achieves an ultralow limit of detection (LOD) of 12.68 ng/ml. The Vernier effect of MFC and the modification of MWCNTs effectively enhance the sensitivity of the STS sensor. The device does not require complex pretreatment or antibody preparation, making it highly promising for applications in food safety, environmental pollution, and health monitoring.

IEEE Sensors JournalVol. 25(2)
Tianjin University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 77%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.