Performance of the Edwards Sapien 3 bioprosthesis in atrioventricular valve position: a case series

Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth. The decrease in leaflet motility in the absence of thrombosis or pannus could be associated with the low-velocity flow and low-pressure gradient that exists between the atria and ventricles in small children. It is well-known graft lifespan is usually shorter in small children, but we hypothesize the possibility of a second factor that valve design is intended to support higher flow-velocity patterns and can present an early failure in low-flow low-pressure situation. More studies are necessary to provide reliable evidence.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Case Reports
Published
2024-11-28
DOI
https://doi.org/10.1093/ehjcr/ytae642
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the Edwards Sapien 3 bioprosthesis in atrioventricular valve position: a case series

Luciana Godoy, Joaquín Fernández-Doblas, Raúl Abella, Ferrán Gran et al.
European Heart Journal - Case Reports
Cardiac Valve Diseases and Treatments
article

Performance of the Edwards Sapien 3 bioprosthesis in atrioventricular valve position: a case series

Luciana Godoy, Joaquín Fernández-Doblas, Raúl Abella, Ferrán Gran, Alejandra Garretano, Paola Dolader, Arantxa Catalán, Pedro Betrián Blasco
article en

Abstract

Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth. The decrease in leaflet motility in the absence of thrombosis or pannus could be associated with the low-velocity flow and low-pressure gradient that exists between the atria and ventricles in small children. It is well-known graft lifespan is usually shorter in small children, but we hypothesize the possibility of a second factor that valve design is intended to support higher flow-velocity patterns and can present an early failure in low-flow low-pressure situation. More studies are necessary to provide reliable evidence.

European Heart Journal - Case ReportsVol. 8(12)
Hospital Arnau de Vilanova (ES), Vall d'Hebron Hospital Universitari (ES)
Responsible consumption and production
Openalex Percentile: Top 58%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.