Adaptive Separate Variational Mode Extraction Method for Noncontact Multivariable Vital Signs Monitoring Using FMCW Radars

The breath rate (BR), heart rate (HR), breathing-breathing interval (BBI), and HR variability (HRV) are the critical vital sign parameters. In this article, a novel method named adaptive separate variational mode extraction (ASVME) algorithm is proposed to accurately monitor multivariable vital signs (MVVSs) at the same time with a frequency-modulated continuous wave (FMCW) radar system in practical scenarios. First, a minimum variance distortionless response (MVDR) spectrum estimation algorithm is proposed to accurately locate respiratory and heartbeat components, which can effectively restrain the influence of respiratory harmonics on HR and R-R intervals (RRIs) measurements. Subsequently, an adaptive variational mode extraction (AVME) algorithm is proposed to accurately extract respiratory waves and heartbeat waves after accurate frequency location. The proposed AVME is an adaptive parameter optimization technique of the variational mode extraction (VME) algorithm based on the high correlation between the extracted signal and the modeled signal as well as the minimum energy loss rate of the extracted signal. Furthermore, an additional sliding window extraction method is proposed in the ASVME method, which further improves the accuracy and stability of the detection of MVVS. The method is verified in a variety of experimental scenarios. The experimental results indicate that the ASVME can accurately detect multivariable vital signs, with the root-mean-square error (RMSE) of the BR and HR demonstrating a high accuracy of 0.46 and 0.80 bpm, respectively, and the RMSE of BBI and RRI being 0.059 and 0.0046 s, respectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Microwave Theory and Techniques
Published
2024-12-11
DOI
https://doi.org/10.1109/tmtt.2024.3510038
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive Separate Variational Mode Extraction Method for Noncontact Multivariable Vital Signs Monitoring Using FMCW Radars

Jun Hu, Zhen Yang
3 citations
IEEE Transactions on Microwave Theory and Techniques
Non-Invasive Vital Sign Monitoring
0.55
article

Adaptive Separate Variational Mode Extraction Method for Noncontact Multivariable Vital Signs Monitoring Using FMCW Radars

Jun Hu, Zhen Yang
article en
3 citations

Abstract

The breath rate (BR), heart rate (HR), breathing-breathing interval (BBI), and HR variability (HRV) are the critical vital sign parameters. In this article, a novel method named adaptive separate variational mode extraction (ASVME) algorithm is proposed to accurately monitor multivariable vital signs (MVVSs) at the same time with a frequency-modulated continuous wave (FMCW) radar system in practical scenarios. First, a minimum variance distortionless response (MVDR) spectrum estimation algorithm is proposed to accurately locate respiratory and heartbeat components, which can effectively restrain the influence of respiratory harmonics on HR and R-R intervals (RRIs) measurements. Subsequently, an adaptive variational mode extraction (AVME) algorithm is proposed to accurately extract respiratory waves and heartbeat waves after accurate frequency location. The proposed AVME is an adaptive parameter optimization technique of the variational mode extraction (VME) algorithm based on the high correlation between the extracted signal and the modeled signal as well as the minimum energy loss rate of the extracted signal. Furthermore, an additional sliding window extraction method is proposed in the ASVME method, which further improves the accuracy and stability of the detection of MVVS. The method is verified in a variety of experimental scenarios. The experimental results indicate that the ASVME can accurately detect multivariable vital signs, with the root-mean-square error (RMSE) of the BR and HR demonstrating a high accuracy of 0.46 and 0.80 bpm, respectively, and the RMSE of BBI and RRI being 0.059 and 0.0046 s, respectively.

IEEE Transactions on Microwave Theory and TechniquesVol. 73(7)
Hefei University of Technology (CN)
National Natural Science Foundation of China, State Key Laboratory of Millimeter Waves, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 36%
Non-Invasive Vital Sign Monitoring
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.