A New Aspect in Analysis and Improvement of Standalone Solar-Driven Absorption Refrigeration Systems

Solar-driven absorption refrigeration systems (ARSs) are subjected to work under off-design conditions due to the driving temperature variation. In this study, a model of NH3/H2O ARS with 100-kW cooling capacity has been developed. Energetic and exergetic coefficients of performance (COP, ECOP), besides cooling production (Qeva), have been investigated at off-design conditions. The analysis indicates a reduction in the effectiveness of the generator and solution heat exchanger (SHX) under such conditions. A new method to improve the off-design system’s performance by modifying the generator and SHX heat capacities is suggested. Results revealed that an increase in heat capacities of the generator and SHX (UAgen, UASHX) effectively improves the system’s performance. Raising the values of UAgen and UASHX by 20% maintains the system’s COP, ECOP, and Qeva near their designed values under a wider range of driving temperatures (100 oC to 92 oC). Moreover, this adjustment helps decrease the system’s cut-in/off temperature.

Authors

Institutions

Publication Details

Journal
Emerging Science Innovation
Published
2024-09-30
DOI
https://doi.org/10.46604/emsi.2024.13833
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Aspect in Analysis and Improvement of Standalone Solar-Driven Absorption Refrigeration Systems

Osman Wageiallah Mohammed, Fathelrahman Ahmed Elmahi
Emerging Science Innovation
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

A New Aspect in Analysis and Improvement of Standalone Solar-Driven Absorption Refrigeration Systems

Osman Wageiallah Mohammed, Fathelrahman Ahmed Elmahi
article en

Abstract

Solar-driven absorption refrigeration systems (ARSs) are subjected to work under off-design conditions due to the driving temperature variation. In this study, a model of NH3/H2O ARS with 100-kW cooling capacity has been developed. Energetic and exergetic coefficients of performance (COP, ECOP), besides cooling production (Qeva), have been investigated at off-design conditions. The analysis indicates a reduction in the effectiveness of the generator and solution heat exchanger (SHX) under such conditions. A new method to improve the off-design system’s performance by modifying the generator and SHX heat capacities is suggested. Results revealed that an increase in heat capacities of the generator and SHX (UAgen, UASHX) effectively improves the system’s performance. Raising the values of UAgen and UASHX by 20% maintains the system’s COP, ECOP, and Qeva near their designed values under a wider range of driving temperatures (100 oC to 92 oC). Moreover, this adjustment helps decrease the system’s cut-in/off temperature.

Emerging Science InnovationVol. 4
Nile Valley University (SD), Red Sea University (SD)
Openalex Percentile: Top 77%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.