Development of a novel test of splenic function for use in a clinical diagnostic laboratory

The spleen is prone to both physical damage and functional impairment, which can be difficult to detect before catastrophic complications occur. Currently available tests of splenic function are laborious, user-dependent and unreliable, so there is an unmet need for a reliable test offered routinely in diagnostic laboratories. In this study, we have assessed a simple flow cytometry-based method measuring high mannose glycans (HMGs) on erythrocytes, which has previously been proposed as a potential test of splenic function. We developed the test as a diagnostic assay using blood from a range of control and potentially hyposplenic samples, including people with sickle cell disease. HMG expression correlated well with manual pit counting, an established method for assessing splenic function (r = 0.6). A threshold of >36% difference compared to the mean of control samples was used to define hyposplenism. At this threshold, the test is 93% sensitive and 100% specific for detecting splenic dysfunction. The test was highly reproducible and stable in blood samples of up to 4 days old. This test is non-invasive with quantitative data output and requires significantly less operator time than other available techniques, making it a robust new clinical assay for determining splenic function.

Authors

Institutions

Publication Details

Journal
British Journal of Haematology
Published
2024-12-10
DOI
https://doi.org/10.1111/bjh.19950
Citations
2
Primary Topic
Abdominal Trauma and Injuries
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a novel test of splenic function for use in a clinical diagnostic laboratory

John Brewin, Huan Cao, Mark A. Vickers, Claire Laas et al.
2 citations
British Journal of Haematology
Abdominal Trauma and Injuries
1.15
article

Development of a novel test of splenic function for use in a clinical diagnostic laboratory

John Brewin, Huan Cao, Mark A. Vickers, Claire Laas, David C. Rees, Barnaby Clark, Victoria Potter, Abdullah Aslam Khan
article en
2 citations

Abstract

The spleen is prone to both physical damage and functional impairment, which can be difficult to detect before catastrophic complications occur. Currently available tests of splenic function are laborious, user-dependent and unreliable, so there is an unmet need for a reliable test offered routinely in diagnostic laboratories. In this study, we have assessed a simple flow cytometry-based method measuring high mannose glycans (HMGs) on erythrocytes, which has previously been proposed as a potential test of splenic function. We developed the test as a diagnostic assay using blood from a range of control and potentially hyposplenic samples, including people with sickle cell disease. HMG expression correlated well with manual pit counting, an established method for assessing splenic function (r = 0.6). A threshold of >36% difference compared to the mean of control samples was used to define hyposplenism. At this threshold, the test is 93% sensitive and 100% specific for detecting splenic dysfunction. The test was highly reproducible and stable in blood samples of up to 4 days old. This test is non-invasive with quantitative data output and requires significantly less operator time than other available techniques, making it a robust new clinical assay for determining splenic function.

British Journal of HaematologyVol. 206(1)
University of Aberdeen (GB), King's College Hospital (GB)
Alzheimer’s Research UK
Openalex Percentile: Top 19%
Abdominal Trauma and Injuries
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a novel test of splenic function for use in a clinical diagnostic laboratory — John Brewin, Huan Cao, et al. · British Journal of Haematology (2024) | TGRS Research Map | TGRS