Water and Oil Volume Measurement Using UV–Visible Spectroscopy

Abstract Fluid saturation in relative permeability experiments is typically determined by volumetric or gravimetric measurements, as well as in-situ saturation monitoring (ISSM). Gravimetric measurements tend to have larger error due to grain loss. The conventional volumetric method used can be a challenge because produced volumes for oil and water must be separated and measured manually. ISSM method is also a costly technique. In this study, an UV–visible spectroscopy was used to continuously and cost effectively measure oil and water volumes. A water-oil unsteady state relative permeability was performed to investigate the feasibility of calculating oil and water volumes using UV–visible spectroscopy. UV–visible spectroscopy is a quantitative technique in analytical chemistry to determine concentrations of known solutes. A UV–visible spectroscope was located in the flow line immediately after the core holder and used to quantify fluid volumes (oil and water) produced from a core sample during unsteady state relative permeability study. A volumetric separator was also used to compare production volumes obtained from UV–visible spectroscope. The relative permeabilities were calculated using JBN method from both volumetric and UV-visible spectroscope measurements and then history matched with Sendra (PRORES AS). The final oil volume produced, oil and water relative permeability curves obtained from UV–visible spectroscope measurements were in good agreement with volumetric measurements. The Corey relative permeability curves simulated from Sendra also were closely matched with analytical relative permeability curves obtained using volume measurements from volumetric and UV–visible spectroscope data. Nuclear Magnetic Resonance (NMR) on post relative permeability experiment was also in good agreement with UV–visible spectroscope measurement. UV–visible spectroscopy was also used to measure the breakthrough time of the injected fluid. Breakthrough time estimated using in-line UV–visible spectrophotometer was 0.634 PVI compared to 0.617 and 0.673 PVI from pressure data and volumetric observations. Graphic Abstract

Authors

Institutions

Publication Details

Journal
Transport in Porous Media
Published
2024-12-10
DOI
https://doi.org/10.1007/s11242-024-02140-6
Citations
1
Primary Topic
NMR spectroscopy and applications
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Water and Oil Volume Measurement Using UV–Visible Spectroscopy

S. Law, Jules Reed, Yukie Tanino, Mohammad Ali Sarlak et al.
1 citations
Transport in Porous Media
NMR spectroscopy and applications
0.66
article

Water and Oil Volume Measurement Using UV–Visible Spectroscopy

S. Law, Jules Reed, Yukie Tanino, Mohammad Ali Sarlak, Alan J. McCue
article en
1 citations

Abstract

Abstract Fluid saturation in relative permeability experiments is typically determined by volumetric or gravimetric measurements, as well as in-situ saturation monitoring (ISSM). Gravimetric measurements tend to have larger error due to grain loss. The conventional volumetric method used can be a challenge because produced volumes for oil and water must be separated and measured manually. ISSM method is also a costly technique. In this study, an UV–visible spectroscopy was used to continuously and cost effectively measure oil and water volumes. A water-oil unsteady state relative permeability was performed to investigate the feasibility of calculating oil and water volumes using UV–visible spectroscopy. UV–visible spectroscopy is a quantitative technique in analytical chemistry to determine concentrations of known solutes. A UV–visible spectroscope was located in the flow line immediately after the core holder and used to quantify fluid volumes (oil and water) produced from a core sample during unsteady state relative permeability study. A volumetric separator was also used to compare production volumes obtained from UV–visible spectroscope. The relative permeabilities were calculated using JBN method from both volumetric and UV-visible spectroscope measurements and then history matched with Sendra (PRORES AS). The final oil volume produced, oil and water relative permeability curves obtained from UV–visible spectroscope measurements were in good agreement with volumetric measurements. The Corey relative permeability curves simulated from Sendra also were closely matched with analytical relative permeability curves obtained using volume measurements from volumetric and UV–visible spectroscope data. Nuclear Magnetic Resonance (NMR) on post relative permeability experiment was also in good agreement with UV–visible spectroscope measurement. UV–visible spectroscopy was also used to measure the breakthrough time of the injected fluid. Breakthrough time estimated using in-line UV–visible spectrophotometer was 0.634 PVI compared to 0.617 and 0.673 PVI from pressure data and volumetric observations. Graphic Abstract

Transport in Porous MediaVol. 152(1)
University of Aberdeen (GB)
University of Aberdeen
Clean water and sanitation
Openalex Percentile: Top 14%
NMR spectroscopy and applications
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.