The Psychophysical Assessments of Tactile, Temperature and Electrical Perception for Implants With Metal Prosthetic Surfaces

Tactile function and thermal perception are 2 primary functions of oral structures. Implants without periodontal ligaments and pulp might fail to sense tactile and temperature changes. This study aimed to investigate implants' tactile, thermal, and electrical perception by detailed psychophysical assessments. A total of 48 patients with single implant restoration were recruited. Mechanical (5 intensities), cold (4 temperatures), and electrical stimulation were, respectively, applied to implants and natural teeth, and the psychophysical results were recorded with a visual analog scale and compared between implants and natural teeth. For tactile perception, at low and medium forces, implants were significantly poorer than natural teeth (P < .01), but at the largest force, there were no significant differences (P > .05). Regarding thermal perception, thermal changes on implants could be detected although the signals were weaker when compared with natural teeth (P < .01). Implants were less sensitive to electrical stimulation than natural teeth (P < .01). Even though there is no periodontium and pulp, dental implants could perceive the mechanical, thermal, and electrical stimulation weakly.

Authors

Institutions

Publication Details

Journal
Journal of Oral Implantology
Published
2024-12-10
DOI
https://doi.org/10.1563/aaid-joi-d-24-00031
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Psychophysical Assessments of Tactile, Temperature and Electrical Perception for Implants With Metal Prosthetic Surfaces

Jianxiang Tao, Jinlang Xue, Qing Fang, Shuai Hu
Journal of Oral Implantology
Muscle activation and electromyography studies
article

The Psychophysical Assessments of Tactile, Temperature and Electrical Perception for Implants With Metal Prosthetic Surfaces

Jianxiang Tao, Jinlang Xue, Qing Fang, Shuai Hu
article en

Abstract

Tactile function and thermal perception are 2 primary functions of oral structures. Implants without periodontal ligaments and pulp might fail to sense tactile and temperature changes. This study aimed to investigate implants' tactile, thermal, and electrical perception by detailed psychophysical assessments. A total of 48 patients with single implant restoration were recruited. Mechanical (5 intensities), cold (4 temperatures), and electrical stimulation were, respectively, applied to implants and natural teeth, and the psychophysical results were recorded with a visual analog scale and compared between implants and natural teeth. For tactile perception, at low and medium forces, implants were significantly poorer than natural teeth (P < .01), but at the largest force, there were no significant differences (P > .05). Regarding thermal perception, thermal changes on implants could be detected although the signals were weaker when compared with natural teeth (P < .01). Implants were less sensitive to electrical stimulation than natural teeth (P < .01). Even though there is no periodontium and pulp, dental implants could perceive the mechanical, thermal, and electrical stimulation weakly.

Journal of Oral ImplantologyVol. 51(1)
Tongji University (CN), Shanghai Stomatological Hospital (CN)
No poverty
Openalex Percentile: Top 79%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Psychophysical Assessments of Tactile, Temperature and Electrical Perception for Implants With Metal Prosthetic Surfaces — Jianxiang Tao, Jinlang Xue, et al. · Journal of Oral Implantology (2024) | TGRS Research Map | TGRS