Performance Evaluation of Molecular Detection of Enteroviruses: Results of 18 Years of Quality Control for Molecular Diagnostics (QCMD) External Quality Assessment Program, 2005−2022

The gold standard for enterovirus (EV) detection is the polymerase chain reaction based on the detection of the 5' untranslated region of the virus. Correct detection of EV is crucial for patient and public health purposes. The performance of diagnostic and public health laboratories on molecular EV-detection was analyzed using data from the external quality assessment program distributed by Quality Control for Molecular Diagnostics (QCMD) between 2005 and 2022. Overall performance on core samples of both laboratory types has improved over the years for in-house or commercial assays (overall performance rate > 94.8%) since 2013. A similar improvement was observed for negative/specificity samples. Performance on EV-positive samples varied, with the lowest performance observed on samples containing enterovirus D68 (B3 strain) and echovirus 11. Significant differences in performance were observed between laboratory and assay types. Performance of diagnostic laboratories (91.8) was significantly higher than of public health laboratories (89.9%; p < 0.0001). Additionally, a significant higher performance of diagnostic laboratories using commercial assays was observed (92.5% vs. 91.2% for in-house assays; p < 0.0001). In contrast, the performance of public health laboratories using in-house assays (90.1%) was higher than commercial assays (89.2%; p = 0.3608). The data document the improved performance of diagnostic and public health laboratories using either commercial or in-house assays.

Authors

Institutions

Publication Details

Journal
Journal of Medical Virology
Published
2024-12-01
DOI
https://doi.org/10.1002/jmv.70103
Citations
2
Primary Topic
Viral Infections and Immunology Research
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of Molecular Detection of Enteroviruses: Results of 18 Years of Quality Control for Molecular Diagnostics (QCMD) External Quality Assessment Program, 2005−2022

Kimberley Benschop, Elaine McCulloch, Greg Sutton, Dorothy Montgomery et al.
2 citations
Journal of Medical Virology
Viral Infections and Immunology Research
0.80
article

Performance Evaluation of Molecular Detection of Enteroviruses: Results of 18 Years of Quality Control for Molecular Diagnostics (QCMD) External Quality Assessment Program, 2005−2022

Kimberley Benschop, Elaine McCulloch, Greg Sutton, Dorothy Montgomery, Oliver Donoso Mantke, Harry Staines, Anton van Loon, Emily Mckloud
article en
2 citations

Abstract

The gold standard for enterovirus (EV) detection is the polymerase chain reaction based on the detection of the 5' untranslated region of the virus. Correct detection of EV is crucial for patient and public health purposes. The performance of diagnostic and public health laboratories on molecular EV-detection was analyzed using data from the external quality assessment program distributed by Quality Control for Molecular Diagnostics (QCMD) between 2005 and 2022. Overall performance on core samples of both laboratory types has improved over the years for in-house or commercial assays (overall performance rate > 94.8%) since 2013. A similar improvement was observed for negative/specificity samples. Performance on EV-positive samples varied, with the lowest performance observed on samples containing enterovirus D68 (B3 strain) and echovirus 11. Significant differences in performance were observed between laboratory and assay types. Performance of diagnostic laboratories (91.8) was significantly higher than of public health laboratories (89.9%; p < 0.0001). Additionally, a significant higher performance of diagnostic laboratories using commercial assays was observed (92.5% vs. 91.2% for in-house assays; p < 0.0001). In contrast, the performance of public health laboratories using in-house assays (90.1%) was higher than commercial assays (89.2%; p = 0.3608). The data document the improved performance of diagnostic and public health laboratories using either commercial or in-house assays.

Journal of Medical VirologyVol. 96(12)
Royal Statistical Society (GB), National Institute for Public Health and the Environment (NL)
Openalex Percentile: Top 22%
Viral Infections and Immunology Research
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.