Combining Germanium Quantum Dots with Porous Silicon: An Innovative Method for X-ray Detection

This study investigates the controlled electrochemical synthesis of porous silicon and germanium (Ge)-doped porous silicon using a 4:1 ratio of hydrofluoric acid (HF) to ethanol. Structural analysis performed with FESEM-EDX confirmed the presence of Ge in the samples. Analysis of the I-V characteristics demonstrated that increasing the bias voltage at the source led to a corresponding increase in the observed current. Additionally, effective X-ray measurements facilitated the assessment of X-ray irradiation effects on the sample detector. The experimental results indicated that the optimal conditions for the porous silicon (PS) and Ge-doped porous silicon (Ge-PS) samples were (90V, 100mA, 1s) and (100V, 10mA, 0.5s), respectively.

Authors

Institutions

Publication Details

Journal
WSEAS TRANSACTIONS ON ELECTRONICS
Published
2024-12-10
DOI
https://doi.org/10.37394/232017.2024.15.15
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Germanium Quantum Dots with Porous Silicon: An Innovative Method for X-ray Detection

Ahmad M. AL-Diabat, Natheer A. Algadri, Tariq AlZoubi, Abdulsalam Abuelsamen et al.
WSEAS TRANSACTIONS ON ELECTRONICS
Advanced Semiconductor Detectors and Materials
article

Combining Germanium Quantum Dots with Porous Silicon: An Innovative Method for X-ray Detection

Ahmad M. AL-Diabat, Natheer A. Algadri, Tariq AlZoubi, Abdulsalam Abuelsamen, Amal Mohamed Ahmed Ali, Osama Abu Noqta, Ghaseb N. Makhadmeh, Naser M. Ahmed, Almutery Aml
article en

Abstract

This study investigates the controlled electrochemical synthesis of porous silicon and germanium (Ge)-doped porous silicon using a 4:1 ratio of hydrofluoric acid (HF) to ethanol. Structural analysis performed with FESEM-EDX confirmed the presence of Ge in the samples. Analysis of the I-V characteristics demonstrated that increasing the bias voltage at the source led to a corresponding increase in the observed current. Additionally, effective X-ray measurements facilitated the assessment of X-ray irradiation effects on the sample detector. The experimental results indicated that the optimal conditions for the porous silicon (PS) and Ge-doped porous silicon (Ge-PS) samples were (90V, 100mA, 1s) and (100V, 10mA, 0.5s), respectively.

WSEAS TRANSACTIONS ON ELECTRONICSVol. 15
Universiti Sains Malaysia (MY), Prince Sattam Bin Abdulaziz University (SA), Al-Zaytoonah University of Jordan (JO), Shaqra University (SA), Skyline University College (AE), American University of the Middle East (KW), Middle East University (JO), Isra University (JO)
University of Jordan
Openalex Percentile: Top 80%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.