Measurement of radon exhalation rate from the surface of cavity and effect analysis of waterproof and radon suppression project in China Jinping Underground Laboratory phase II

<p indent="0mm">Radon is a major contributor to environmental radiation in underground laboratories. The Deep Underground and Ultra-low Radiation Background Facility for frontier physics experiments (DURF), a National Major Science and Technology Infrastructure Project, is being built based on phase II of the China Jinping Underground laboratory (CJPL-II). Through the installation of a new ventilation system and a waterproof radon-suppression layers, radon in the underground lab air is effectively controlled. To assess the effectiveness of the radon suppression project, including the impact of the waterproof radon-suppression layers on radon exhalation from the surrounding rock, as well as its overall effectiveness in reducing air radon concentrations, a surface radon exhalation rate detector was employed to measure radon exhalation rates from various surfaces of the waterproof radon-suppression layers. Additionally, radon concentrations and gamma background from radon progeny were measured using the AlphaGuard and a portable high-purity germanium spectrometer before and after the radon suppression project. The results revealed that following the installation of the waterproof radon-suppression layers, the surface radon exhalation rate dropped to less than 1% of the rock exhalation rate, with all experiment halls showing exhalation rates below 0.1 mBq m<sup>−2</sup> s<sup>−1</sup>. The count rates of the characteristic peaks of <sup>214</sup>Pb and <sup>214</sup>Bi in the <italic>in-situ</italic> gamma spectrum were reduced by about 60%, and the contribution of radon progeny <sup>214</sup>Pb and <sup>214</sup>Bi to the characteristic peaks in the spectrum decreased by approximately 20%–40%. The radon concentration in the experiment halls decreased to <sc>(20.3±0.1) Bq m<sup>‒</sup><sup>3</sup>,</sc> roughly one-tenth of the pre-construction level of <sc>(208.0±0.1) Bq m<sup>−3</sup>.</sc> These findings demonstrate that the radon suppression project successfully lowered radon and its progeny concentrations, laying a strong foundation for maintaining a low-background environment in the Phase II laboratory.

Authors

Publication Details

Journal
Zhongguo kexue. Wulixue Lixue Tianwenxue
Published
2024-12-10
DOI
https://doi.org/10.1360/sspma-2024-0435
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of radon exhalation rate from the surface of cavity and effect analysis of waterproof and radon suppression project in China Jinping Underground Laboratory phase II

Pengcheng Xu, Tao Xue, J. Cheng, Mingkun Jing et al.
Zhongguo kexue. Wulixue Lixue Tianwenxue
Radioactivity and Radon Measurements
article

Measurement of radon exhalation rate from the surface of cavity and effect analysis of waterproof and radon suppression project in China Jinping Underground Laboratory phase II

Pengcheng Xu, Tao Xue, J. Cheng, Mingkun Jing, Peng Zhang, Hao Ma, Qiuli Zhang, W. H. Dai, Zhi Ceng
article en

Abstract

<p indent="0mm">Radon is a major contributor to environmental radiation in underground laboratories. The Deep Underground and Ultra-low Radiation Background Facility for frontier physics experiments (DURF), a National Major Science and Technology Infrastructure Project, is being built based on phase II of the China Jinping Underground laboratory (CJPL-II). Through the installation of a new ventilation system and a waterproof radon-suppression layers, radon in the underground lab air is effectively controlled. To assess the effectiveness of the radon suppression project, including the impact of the waterproof radon-suppression layers on radon exhalation from the surrounding rock, as well as its overall effectiveness in reducing air radon concentrations, a surface radon exhalation rate detector was employed to measure radon exhalation rates from various surfaces of the waterproof radon-suppression layers. Additionally, radon concentrations and gamma background from radon progeny were measured using the AlphaGuard and a portable high-purity germanium spectrometer before and after the radon suppression project. The results revealed that following the installation of the waterproof radon-suppression layers, the surface radon exhalation rate dropped to less than 1% of the rock exhalation rate, with all experiment halls showing exhalation rates below 0.1 mBq m<sup>−2</sup> s<sup>−1</sup>. The count rates of the characteristic peaks of <sup>214</sup>Pb and <sup>214</sup>Bi in the <italic>in-situ</italic> gamma spectrum were reduced by about 60%, and the contribution of radon progeny <sup>214</sup>Pb and <sup>214</sup>Bi to the characteristic peaks in the spectrum decreased by approximately 20%–40%. The radon concentration in the experiment halls decreased to <sc>(20.3±0.1) Bq m<sup>‒</sup><sup>3</sup>,</sc> roughly one-tenth of the pre-construction level of <sc>(208.0±0.1) Bq m<sup>−3</sup>.</sc> These findings demonstrate that the radon suppression project successfully lowered radon and its progeny concentrations, laying a strong foundation for maintaining a low-background environment in the Phase II laboratory.

Zhongguo kexue. Wulixue Lixue TianwenxueVol. 55(11)
Openalex Percentile: Top 66%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.