<i>In situ</i> developed NiCo<sub>2</sub>O<sub>4</sub>–Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> nanohybrid towards non-enzymatic electrochemical detection of glucose and hydrogen peroxide
Owing to the adverse consequences of excess glucose (Glu) and hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) on humans, it is imperative to develop an electrochemical sensor for detection of these analytes with good selectivity and sensitivity. Herein, a nanohybrid comprising nickel cobaltite nanoparticles (NiCo<sub>2</sub>O<sub>4</sub> NPs) embedded on conductive Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> nanosheets (NSs) has been prudently designed and employed for the electrochemical detection of Glu and H<sub>2</sub>O<sub>2</sub>. The developed nanohybrid has been systematically characterized using morphological and spectral techniques, and then immobilized on a glassy carbon electrode (GCE). Under optimized conditions, the developed NiCo<sub>2</sub>O<sub>4</sub>-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub>/GCE based electrochemical sensor has demonstrated an impressive analytical response towards Glu and H<sub>2</sub>O<sub>2</sub> with good sensitivity and selectivity. The non-enzymatic sensor has demonstrated a broad linear range from 30 μM to 1.83 mM for Glu, and two linear ranges of 20-100 μM and 100 μM-2.01 mM for H<sub>2</sub>O<sub>2</sub>. The sensor has exhibited limits of detection (LOD) of 9 μM and 6 μM with sensitivities of 101.2 μA μM<sup>-1</sup> cm<sup>-2</sup> and 107.03 μA μM<sup>-1</sup> cm<sup>-2</sup>, respectively, for Glu and H<sub>2</sub>O<sub>2</sub> detection. The impressive analytical performance of the fabricated sensor in terms of linear range, LOD and sensitivity are ascribed to the (i) enhanced conductivity of Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> NSs, (ii) mediated electrocatalytic activity of NiCo<sub>2</sub>O<sub>4</sub> NPs and (iii) large number of catalytically active sites on the NiCo<sub>2</sub>O<sub>4</sub>-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> heterostructure. Notably, the NiCo<sub>2</sub>O<sub>4</sub>-Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub>/GCE has demonstrated impressive stability and reproducibility, which is mainly due to the <i>in situ</i> uniform growth of NiCo<sub>2</sub>O<sub>4</sub> NPs over Ti<sub>3</sub>C<sub>2</sub>T<sub><i>x</i></sub> NSs.
Authors
- Kathavarayan Thenmozhi (ORCID: https://orcid.org/0000-0002-9016-5380)
- Devarasu Mohanapriya (ORCID: https://orcid.org/0009-0000-8693-4901)
Institutions
- Vellore Institute of Technology University (IN)
Publication Details
- Journal
- Journal of Materials Chemistry B
- Published
- 2024-12-10
- DOI
- https://doi.org/10.1039/d4tb02265c
- Citations
- 14
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 2.92