Wind Uplift Resistance of Discontinuous Metal Roofing Systems: Literature Review and Experimental Research

Damage to building envelopes, roofing, and wall cladding systems remains a major concern during high wind speed events such as hurricanes and tornadoes. Roofing systems are particularly vulnerable to wind damage, which can lead to extensive water leakage and damage to building contents, even when the structural system remains intact. Hence, ongoing research to improve the wind resistance of roofing materials is of great importance. This paper focuses on the wind load resistance of discontinuous metal roofing (DMR) systems, which are cladding systems assembled with individual panels that have numerous joints that facilitate air flow into and out of the cavity space between the roofing system and structural deck. Experimental research was conducted to establish whether DMR systems are air-permeable, and if so, to develop procedures that evaluate appropriate net wind pressures and pressure equalization factor (PEF) values for their design. First, wind tunnel tests were conducted on 6 by 8 ft DMR roofing specimens to measure the net wind uplift pressure coefficients on DMR systems located in simulated wind flow reattachment zones of the roof. A second experiment sought to measure the net wind pressure and PEF value across a single DMR panel subjected to suction in an air pressure chamber. Both experimental results were compared to PEF values obtained from full-scale tests conducted at the Insurance Institute for Business & Home Safety. The results showed that air permeable DMR systems experience net surface pressures related to the magnitude of external wind pressure by a PEF and so accurate determination of the PEF can only be achieved by reproducing the appropriate spatial pressure distribution on a test specimen during tests. Ultimately, this research highlights inaccuracies in current testing methodologies and the importance of importance of ongoing efforts to enhance the wind resistance of roofing materials and mitigate damage during high wind speed events.

Authors

Institutions

Publication Details

Journal
Journal of Architectural Engineering
Published
2024-12-10
DOI
https://doi.org/10.1061/jaeied.aeeng-1867
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wind Uplift Resistance of Discontinuous Metal Roofing Systems: Literature Review and Experimental Research

Aaron H. Phillips, David O. Prevatt, Oscar Lafontaine, James Bush et al.
Journal of Architectural Engineering
Wind and Air Flow Studies
article

Wind Uplift Resistance of Discontinuous Metal Roofing Systems: Literature Review and Experimental Research

Aaron H. Phillips, David O. Prevatt, Oscar Lafontaine, James Bush, Irina N. Afanasyeva, Scott Kriner, Rob Anderson, David B. Roueche, Robert Zabcik
article en

Abstract

Damage to building envelopes, roofing, and wall cladding systems remains a major concern during high wind speed events such as hurricanes and tornadoes. Roofing systems are particularly vulnerable to wind damage, which can lead to extensive water leakage and damage to building contents, even when the structural system remains intact. Hence, ongoing research to improve the wind resistance of roofing materials is of great importance. This paper focuses on the wind load resistance of discontinuous metal roofing (DMR) systems, which are cladding systems assembled with individual panels that have numerous joints that facilitate air flow into and out of the cavity space between the roofing system and structural deck. Experimental research was conducted to establish whether DMR systems are air-permeable, and if so, to develop procedures that evaluate appropriate net wind pressures and pressure equalization factor (PEF) values for their design. First, wind tunnel tests were conducted on 6 by 8 ft DMR roofing specimens to measure the net wind uplift pressure coefficients on DMR systems located in simulated wind flow reattachment zones of the roof. A second experiment sought to measure the net wind pressure and PEF value across a single DMR panel subjected to suction in an air pressure chamber. Both experimental results were compared to PEF values obtained from full-scale tests conducted at the Insurance Institute for Business & Home Safety. The results showed that air permeable DMR systems experience net surface pressures related to the magnitude of external wind pressure by a PEF and so accurate determination of the PEF can only be achieved by reproducing the appropriate spatial pressure distribution on a test specimen during tests. Ultimately, this research highlights inaccuracies in current testing methodologies and the importance of importance of ongoing efforts to enhance the wind resistance of roofing materials and mitigate damage during high wind speed events.

Journal of Architectural EngineeringVol. 31(1)
University of Florida (US), University of Arkansas at Fayetteville (US), Auburn University (US), Sias University (CN)
Openalex Percentile: Top 80%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.