Comparing the Pressure on the Carpal Tunnel When Using an Ergonomic Pointer Driver and an Optical Alternative

<b>Objectives</b>: The objective of this paper is to introduce a method to measure the force or pressure over the carpal tunnel indirectly, using a new device to drive the pointer of a computer system. The measurements were compared with those obtained using an ergonomic mouse. Simultaneously, measurements of muscular stress on the digitorum extensor muscle were performed to correlate the applied force against muscle activity. <b>Methods</b>: An experimental setup was constructed using an infrared static receiver plus two wearable moving light emitters, which can be displaced inside a rectangular projected region. The pointer functions are performed through two finger gestures, while the hand is naturally extended. A microcontroller was used to communicate with the computer, which works as a human interface device and possesses firmware to associate the position of each light source with the pointer functions. Meanwhile, force and electromyography sensing circuits were developed to transmit and measure carpal tunnel strength and muscular stress. The system was tested on five healthy volunteers, who were encouraged to solve the same computational tasks using this new device and a trademark ergonomic mouse. <b>Results</b>: Our results show great differences (greater than one magnitude) between the efforts of the same volunteers performing the same predefined tasks using both pointer controllers. Only when the new device was used did the Pearson's correlation coefficients show a higher correlation between the effort measured on the carpal tunnel and the muscular activity. <b>Conclusions</b>: The optic pointer driver diminishes the strength on the carpal tunnel, causing slightly increased stress on the digitorum extensor muscle.

Authors

Institutions

Publication Details

Journal
Journal of Functional Morphology and Kinesiology
Published
2024-12-07
DOI
https://doi.org/10.3390/jfmk9040260
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing the Pressure on the Carpal Tunnel When Using an Ergonomic Pointer Driver and an Optical Alternative

Rodolfo Hernández‐Gutiérrez, M. E. Cano, Luis Héctor Quintero Hernández, Zaira López et al.
Journal of Functional Morphology and Kinesiology
Orthopedic Surgery and Rehabilitation
article

Comparing the Pressure on the Carpal Tunnel When Using an Ergonomic Pointer Driver and an Optical Alternative

Rodolfo Hernández‐Gutiérrez, M. E. Cano, Luis Héctor Quintero Hernández, Zaira López, Francisco A. Cholico, E. A. Mena-Barboza, Alfonso Hernández-Sámano, José A. Paz, Celso Velásquez, J. Bernal‐Alvarado
article en

Abstract

<b>Objectives</b>: The objective of this paper is to introduce a method to measure the force or pressure over the carpal tunnel indirectly, using a new device to drive the pointer of a computer system. The measurements were compared with those obtained using an ergonomic mouse. Simultaneously, measurements of muscular stress on the digitorum extensor muscle were performed to correlate the applied force against muscle activity. <b>Methods</b>: An experimental setup was constructed using an infrared static receiver plus two wearable moving light emitters, which can be displaced inside a rectangular projected region. The pointer functions are performed through two finger gestures, while the hand is naturally extended. A microcontroller was used to communicate with the computer, which works as a human interface device and possesses firmware to associate the position of each light source with the pointer functions. Meanwhile, force and electromyography sensing circuits were developed to transmit and measure carpal tunnel strength and muscular stress. The system was tested on five healthy volunteers, who were encouraged to solve the same computational tasks using this new device and a trademark ergonomic mouse. <b>Results</b>: Our results show great differences (greater than one magnitude) between the efforts of the same volunteers performing the same predefined tasks using both pointer controllers. Only when the new device was used did the Pearson's correlation coefficients show a higher correlation between the effort measured on the carpal tunnel and the muscular activity. <b>Conclusions</b>: The optic pointer driver diminishes the strength on the carpal tunnel, causing slightly increased stress on the digitorum extensor muscle.

Journal of Functional Morphology and KinesiologyVol. 9(4)
Universidad de Guanajuato (MX), Universidad de Guadalajara (MX), Secretaría de Salud de Jalisco (MX), Universidad de la Ciénega (MX), Centro de Investigación y Asistencia en Tecnología y Diseño del Estado de Jalisco (MX)
Consejo Nacional de Ciencia y Tecnología
Openalex Percentile: Top 58%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.